Firmware Manual
9000X AF Drives
6-26 For more information visit: www.eaton.com
MN04004001E
August 2010
Multi-Purpose Control Application
Keypad Control (Control Keypad: Menu M2)
The parameters for the selection of control place and direction on the keypad are listed
below. See the Keypad control menu in the 9000X AF Drives User Manual.
Table 6-28: Keypad Control Parameters — M2
System Menu (Control Keypad: Menu M5)
For parameters and functions related to the general use of the drive, such as application
and language selection, customized parameter sets or information about the hardware and
software, see Chapter 5 in the 9000X AF Drives User Manual.
Expander Boards (Control Keypad: Menu M6)
The M6 menu shows the expander and option boards attached to the control board and
board-related information. For more information, see Chapter 5 in the 9000X AF Drives
User Manual.
Code Parameter Min. Max. Unit Default Cust ID Note
P2.1 Control place 0 2 0 Keypad
L/R
1685 0 = Keypad L/R
1 = Local
2 = Remote
3 = I/O Select
R2.2 Keypad reference Par.
1.1.1
Par. 1.1.2 Hz
P2.3 Direction (on
keypad)
0 1 0 123 0 = Forward
1 = Reverse
P2.4 Stop button 0 1 1 114 0 = Limited function of
Stop button
1 = Stop button always
enabled
R2.5 Torque reference 0.0 100.0 % 0.0
P2.6 Hide Operate M 0 1 0/No 1707 0 = No
1 = Yes