Specifications
46
EATON CORPORATION Reference Guide & Pricebook
January 1, 2012
5125 RACKMOUNT SERVICE PLANS
Contract Onsite Gold Plan List Onsite Gold Plan List
Product Duration Part Number Price Plus Part Number Price
5000–6000 VA 2 YR 2OSGX51256000CX $557 2OSGP51256000CX $1,142
3 YR 3OSGX51256000CX $1,027 3OSGP51256000CX $1,984
5 YR 5OSGX51256000CX $1,633 5OSGP51256000CX $2,723
Base Unit 7x24 Service Adders
Contract Onsite Gold Plan List Onsite Gold Plan List
Product Duration Part Number Price Plus Part Number Price
7x24 Base 2 YR 2OSGX5100BASEC7 $327 2OSGP5100BASEC7 $534
Adder 3 YR 3OSGX5100BASEC7 $367 3OSGP5100BASEC7 $781
5 YR 5OSGX5100BASEC7 $424 5OSGP5100BASEC7 $1,211
External Battery Module Adder Service Plan
Contract Onsite Gold Plan List Onsite Gold Plan List
Product Duration Part Number Price Plus Part Number Price
EBM 240 2 YR 2OSGX5125B240CX $327 2OSGP5125B240CX $805
PW5125 3 YR 3OSGX5125B240CX $786 3OSGP5125B240CX $1,743
5000/6000VA 5 YR 5OSGX5125B240CX $1,705 5OSGP5125B240CX $2,661
External Battery Module 7x24 Service Adders
Contract Onsite Gold Plan List Onsite Gold Plan List
Product Duration Part Number Price Plus Part Number Price
7x24 2 YR 2OSGX5100EBMXC7 $165 2OSGP5100EBCXC7 $268
Battery 3 YR 3OSGX5100EBMXC7 $184 3OSGP5100EBCXC7 $391
Adder 5 YR 5OSGX5100EBMXC7 $213 5OSGP5100EBCXC7 $606
To cover both the base UPS and Extended Battery Modules, the EBM Gold Plan(s) should be added to the like UPS Gold Plan(s). Unit must be within 100 miles of an established service location to
qualify for 24-hour response and is per contracted period of maintenance. Initial startup serves as the performance check during the first year of the Onsite Gold Plan Plus. UPS Gold Plan covers
standard, internal batteries.
Startup and Preventive Maintenance Service
Product Part Number List Price Product Part Number List Price
Onsite Startup Onsite Preventive Maintenance
5x8 Service 0STUP5100XALLC5 $778 5x8 Service 0XXPM5100XALLC5 $778
7x24 Service 0STUP5100XALLC7 $1,002 7x24 Service 0XXPM5100XALLC7 $1,002
Additional information about service plan features can be found in the Single-Phase Service Plans Overview section of this reference guide.
5125 RACKMOUNT BATTERY BACKUP
TIMES (in minutes) @ 0.9 Power Factor
Standard
Load (VA/Watts) Internal Batteries +1 EBM +2 EBMs +3 EBMs +4 EBMs
1000/900 59 169 303 452 612
2000/1800 26 79 138 204 274
2200/1980 21 65 112 164 223
2500/2250 19 61 106 156 210
2700/2430 17 52 89 132 180
3000/2700 15 49 85 125 168
3500/3150 13 43 73 110 142
4500/4050 8 27 52 76 102
5000/4500 7 24 46 67 89
5500/4950 6 22 42 61 81
6000/5400 5 19 36 53 71
Note: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
EATON 5125 UPS RACKMOUNT
Powerware series (continued)
View interactive runtime graphs
at www.eaton.com/5125rm