SURGE PROTECTION
Surge Protection Devices (SPD)
SPD Type 1 CHSP Service Entrance Surge Protection — UL 1449 3rd Ed. Listed
Commercial grade AC power protection
Type 1 surge device for installation before or after the main service disconnect
Convenient mounting options—universal fit to any manufacturers equipment
Clear, visible LED indication displaying status of the surge protector
SPD TYPE 1 CHSP
Surge Current
Catalog Frequency Capacity, Per List
Number Enclosure Voltage Phase (Hz) MCOV
1
VPR
2
I
n
3
SCCR
4
Phase Rating
5
Price
CHSPT1ULTRA NEMA 4 100/200, 110/220, 120/240 Single 50/60 L-L 300, L-L 1000, 20 kA 200 kA 50 kA $1,330
L-N 150 L-N 600
CHSPT1MAX NEMA 4 100/200, 110/220, 120/240 Single 50/60 L-L 300, L-L 1000, 20 kA 200 kA 45 kA $1,005
L-N 150 L-N 600
CHSPT1MICRO NEMA 4 100/200, 110/220, 120/240 Single 50/60 L-L 300, L-L 1000, 20 kA 200 kA 36 kA $678
L-N 150 L-N 600
CHSPT1-208Y NEMA 4 120/208 Three-phase 50/60 L-L 300, L-L 1000, 20 kA 200 kA 50 kA $1,330
wye L-N 150 L-N 600
Notes:
1. MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. 2. VPR: Voltage Protection Rating is the measured limiting voltage after a surge event.
3. I
n
: Nominal Discharge Current is the current that the device can withstand for 15 impulses. 4. SCCR: The amount of current the product can withstand under short-circuit conditions
5. Surge Current Capacity: The maximum one time surge current rating per phase
For warranty details, go to www.eaton.com/surgetrap
SPD Type 2 CHSP Service Entrance Surge Protection — UL 1449 3rd Ed.; cUL
AC power protection
Universally connects to any manufacturers loadcenter (breaker box)
Quick connect design—easy to mount telephone and cable protection modules
LED status indication
This product should be connected on the load side of the loadcenter main service
disconnect through a dedicated circuit breaker (follow NEC Guidelines)
SPD TYPE 2 CHSP
Surge Current
Catalog Frequency Capacity, Per List
Number Enclosure Voltage Phase (Hz) MCOV
1
VPR
2
I
n
3
SCCR
4
Phase Rating
5
Price
CHSPT2ULTRA NEMA 4 120/240 Vac Single 60 150V L-N, 600V L-N, 1000V L-L, 20 kA 22 kA 108 kA (L1-N 54 kA, L1-G $1,010
rated line voltage 300V L-L 800V N-G, 600V L-G 54 kA, L2-N 54 kA, L2-G 54 kA)
CHSPT2MAX NEMA 4 120/240 Vac Single 60 150V L-N, 600V L-N, 1000V L-L, 10 kA 22 kA 72 kA (L1-N 36 kA, L1-G $537
rated line voltage 300V L-L 800V N-G, 600V L-G 36 kA, L2-N 36 kA, L2-G 36 kA)
CHSPT2MICRO NEMA 4 120/240 Vac Single 60 150V L-N, 600V L-N, 1000V L-L, 5 kA 22 kA 36 kA (L1-N 18 kA, L1-G $336
rated line voltage 300V L-L 800V N-G, 600V L-G 18 kA, L2-N 18 kA, L2-G 18 kA)
Notes:
1. MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. 2. VPR: Voltage Protection Rating is the measured limiting voltage after a surge event.
3. I
n
: Nominal Discharge Current is the current that the device can withstand for 15 impulses. 4. SCCR: The amount of current the product can withstand under short-circuit conditions
5. Surge Current Capacity: The maximum one time surge current rating per phase.
For warranty details, go to www.eaton.com/surgetrap