Specifications
116
EATON CORPORATION Reference Guide & Pricebook
January 1, 2012
EATON 9390IT UPS
Powerware series (continued)
NON-MATCHING MAINTENANCE BYPASS PANELS (40 kVA)
(continued)
Part Input/Output Dimensions Weight List
Number Description Rating (amps) Voltage (H x W x D, inches) (lb) Price
M90BGA1XXX Maintenance bypass, 208/208V, three-breaker 175 208/208 73.0 x 24.0 x 11.5 400 $4,711
65 kAIC (175A MIS/MBP/BIB)
M90BEE1XXX Maintenance bypass, 480/480V, three-breaker 100 480/480 73.0 x 24.0 x 11.5 400 $3,359
10 kAIC (100A MIS/MBP/BIB)
M90BFE1XXX Maintenance bypass, 480/480V, three-breaker 70 480/480 73.0 x 24.0 x 11.5 400 $4,087
35 kAIC (70A MIS/MBP/BIB)
M90BGE1XXX Maintenance bypass, 480/480V, three-breaker 70 480/480 73.0 x 24.0 x 11.5 400 $4,503
65 kAIC (70A MIS/MBP/BIB)
MISCELLANEOUS PARTS
Part Number Description List Price
103006244 REPO switch, wall-mount
1
$426
103004223 Remote Monitor Panel "RMP II"
2
$1,113
103004221 Relay Interface Module "RIM II"
2
$1,092
103004222 Supervisory Contact Module "SCM II"
2
$1,206
103007974-5591 Power Xpert Gateway UPS Card $450
103004336 HotSync CAN Bridge Card, (used for paralleling units and/or RMP II/RIM II/SCM II interface)
3
$530
103004179 9390 UPS/IDC seismic mounting kit
4
$718
103001040 9390 output sync control box, 208 Vac $11,336
103001041 9390 output sync control box, 480 Vac $7,072
103003876 UPS/ battery cabinet/ IDC side panel kit $738
152601664 Battery cabinet to battery cabinet interconnect cables (IBC-S cabinet) $73
152601526 Battery cabinet to battery cabinet interconnect cables (IBC-L cabinet) $73
Notes
1. UPS EPO is selectable as N/O or N/C. 2. Requires HotSync CAN Bridge Card to interface with these devices (only one CAN card required for up to four remote devices). Each UPM requires one card for
paralleling. Same card can be used for communication to RS485 devices (RMP II, RIM II, SCM II). Remote devices (RMP II, RIM II, SCM II) require protected 120V AC source hardwired to the device. 3.
HotSync CAN Bridge Card for parallel operation requires Eaton Service Engineer to configure. 4. 40–80 kVA IDC Seismic kit cannot be installed in the field. Must be factory installed. Order via CTO.
9390IT BATTERY BACKUP TIMES (in minutes)*
Load (VA/Watts) UPS w/Internal Battery
40,000 / 36,000 8.3
36,000 / 32,400 9.9
32,000 / 28,800 11.7
28,000 / 25,200 14.5
24,000 / 21,600 17.2
20,000 / 18,000 21.8
16,000 / 14,400 30.1
12,000 / 10,800 42.7
8,000 / 7,200 60.0
4,000 / 3,600 86.5
* Battery backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
9390IT SERVICE PLANS
Description Service Part Number Additional List Price
for UPS Information Per Year
Startup
Startup, After Hours (7x24) W2SU05NXXX-0050 9390-IT $2,174
Startup, Business Hours (5x8) W2SU06NXXX-0050 9390-IT $1,685
Startup, After Hours (7x24)
W2SU05NXXX-0080 9390-IT (80KVA) $2,349
Startup, Business Hours (5x8)
W2SU06NXXX-0080 9390-IT (80KVA) $1,785
Upgrade from 5x8 to 7x24 Startup (5x8 startup included with 9390IT UPS)
UPC05CXXX-0050 9390-IT $532
Startup, After Hours (7x24) W2SU05NXXX-0160 9390-IT (120/160KVA) $2,988
Startup, Business Hours (5x8) W2SU06NXXX-0160 9390-IT (120/160KVA) $2,271