Eaton www.eaton.com 11
Eaton SPD Series for Mounting External
to Electrical Distribution Equipment
Description Specification
Surge current capacity per phase 50, 80, 100, 120, 160, 200, 250, 300, 400 kA ratings available
Nominal discharge current (I
n
) 20kA
Short circuit current rating (SCCR) 200kA
SPD Type Basic feature package = Type 1 (can also be used in Type 2 applications)
Standard and Standard with Surge Counter feature packages = Type 2
Enclosure Types NEMA 1, NEMA 4, NEMA 4X (304 SST)
Standard split phase voltages available 120/240
Single phase 230
Three phase wye system voltages available 120/208, 127/220, 230/400, 277/480, 347/600
Three phase delta system voltages 240, 480, 600
Three phase high leg delta system voltages 120/240
Phase wire length 48” of 10AWG extend beyond the conduit hub
Relay wire length (optional) 48” of 14AWG extend beyond the conduit hub
RoHS Compliant Yes
Internal Disconnect (optional) Eaton 30 Amp FDC Circuit Breaker, Type MCCB
Input Power Frequency 50/60 Hz
Power consumption (Basic units)
208Y, 220Y, 230L, 240S, 240D, and 240H voltage codes 0.5W
400Y and 480Y and 480D voltage codes 1.1W
600Y and 600D voltage codes 1.3W
Power consumption (Standard and Standard with Surge Counter units)
208Y, 220Y, 230L, 240S, 240D, and 240H voltage codes 0.6W
400Y, 480Y, and 480D Basic voltage codes 1.7W
600Y and 600D voltage codes 2.1W
Protection modes Single split phase ...L-N, L-G, N-G, L-L Single phase... L-N, L-G, N-G Three phase delta...L-G, L-L
Three phase Wye.....L-N, L-G, N-G, L-L Three phase high leg delta....L-N, L-G, N-G, L-L
Maximum continuous operating voltage (MCOV)
208Y, 220Y, 240S, 240D, and 240H voltage codes
150 L-N,150 L-G, 150 N-G, 300 L-L
230L, 400Y and 480Y voltage codes 320 L-N, 320 L-G, 320 N-G, 640 L-L
600Y voltage code 420 L-N, 420 L-G, 420 N-G, 840 L-L
240 D voltage code 320 L-G, 320 L-L
480 D voltage code 640L- L-G, 640 L-L
600D voltage code 840 L-G, 840 L-L
Ports 1
Operating temperature -40F to 122F (-40C to 50C)
Operating humidity 5% through 95%, non-condensing
Weight Reference Figures 2, 3, 4, 5, and 6 on pages 4, 5 and 6
Form C relay contact ratings 150 Vac or 125 Vdc, 1A maximum
Form C relay contact loogic Power on, normal state - NO contact = OPEN, NC contact = CLOSED
Power off, fault state, - NO contact = CLOSED, NC contact = OPEN
EMI/RFI filtering attenuation (Standard and Standard With Surge Counter Up to 50 dB from 10 kHz to 100 MHz
Agency certifications and approvals UL1449 3rd Edition listed, CSA (excludes 230L voltage code)
UL1283 (Type 2 SPDs only).
Warranty 10 Years, 15 Years if the product is properly registered with Eaton.
5.0 Specifications
Table 3. Specifications