Datasheet
01/16/2017 171281 - HPL-ED2016 V28.0 EN 2 / 3
SL7-
AP…
Continuous
tone
approx.
2800
- - 100
Pulsed
tone
approx.
2800
approx.
2 Hz
- 100
Sound pressure dB 100
Sound pressure level adjustment Built-in, potentiometer
Sound_pressure_can_be_lowered_to_a_minimum_of 88 dB
Transmission angle 360°
Current-/power consumption
24 V AC/DC A 0.092
Voltage levels 24 V AC/DC ± 10 %
Design�verification�as�per�IEC/EN�61439
Technical data for design verification
Operating ambient temperature min. °C -30
Operating ambient temperature max. °C 60
Technical�data�ETIM�6.0
Low-voltage industrial components (EG000017) / Acoustic module for signal tower (EC001261)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Signal column element, acoustic (ecl@ss8.1-27-37-12-37
[AKF055011])
Function Continuous tone/pulse tone
Outer diameter mm 73
Degree of protection (IP) IP66
Colour Black
Operating voltage at AC 50 Hz V 24 - 24
Operating voltage at AC 60 Hz V 24 - 24
Operating voltage at DC V 24 - 24
Voltage type AC/DC
Tone adjustable Yes
Approvals
Product Standards IEC/EN 60947-5-1; UL 508; CSA-C22.2 No. 14-10; CSA-C22.2 No. 94-91; CE marking
UL File No. E29184
UL Category Control No. NKCR
CSA File No. UL report applies to both US and Canada
CSA Class No. NKCR7
North America Certification UL listed, certified by UL for use in Canada
Degree of Protection UL Type 4, 4X, 13