Use and Care Manual

CORE Lighting Controls
b. Data jack (9557) shall be designed to mate with standard 8-conductor modular jacks and be
compatible with 2, 4, 6, 8 conductor lines.
c. Telephone jack (9556) shall be designed to mate with standard 4- or 6-conductor modular jacks,
and be compatible with 2, 4, or 6 conductor lines. Telephone jacks shall meet FCC Part 68, paragraph
F standards to ensure compatibility with U.S. telephone systems.
d. Cable TV jacks (9555) shall be the coaxial type, designed for use with standard 75-Ohm cables.
C. ASPIRE Screwless Wallplates
1. Wallplates shall be manufactured from durable polycarbonate plastic with gloss finish, and shall attach to
the basic components without using exposed hardware or screws.
2. Multigang wallplates shall provide a continuous, seamless cover for up to six-ganged (9521, 9522, 9523,
9524, 9525, 9526, 9527) decorator-style control and accessory combinations with no exposed hardware or
screws.
3. Modular communication mid-size wallplates shall provide a seamless cover for up to six ports (9550, 9551,
9552, 9553, 9554) for use with jacks and adapters with no exposed hardware or screws.
4. Multigang wallplates shall include an adapter plate for proper device alignment and wallplate attachment.
5. Control, accessory and wallplate profiles shall not exceed 0.30 inches from wall surface to faceplate front
surface.
6. To ensure a precise color match between all plastic parts, color variation of any gloss finish control or
wallplate shall not exceed a delta E of 1, CIE L*a*b* color units, as defined in ASTM E 308-99.
7. Visible parts of dimmers, switches, standard receptacles, cable jacks or any wallplate shall exhibit ultraviolet
stability when tested with multiple actinic light sources as defined in ASTM D4674-89.
2.03 SOURCE QUALITY CONTROL
A. All controls shall be 100% functionally tested at the time of manufacture. Statistical sampling plan shall not be
acceptable.
PART 3 — EXECUTION
3.01 INSTALLATION
A. Contractor shall furnish all devices, labor and other services necessary for the proper installation of the devices as
indicated on the drawings and specified herein.
B. Contractor shall be responsible for de-rating lighting controls capacity in multi-gang installations.
C. Devices shall be installed utilizing manufacturer’s recommended application, wiring and installation instructions.
D. Contractor shall provide frameless wallplate covers per specification 2.02 for all devices ganged in a common box.
Contractor shall provide barriers within the box where required by code.
3.02 FIELD QUALITY CONTROL
A. Cooper Wiring Devices technical hotline available 8:00AM–6:00PM E.S.T. Monday–Friday: 1-866-853-4293
B. Supplemental information shall be provided on the Cooper Wiring Device website at www.cooperwiringdevices.com
Cooper Wiring Devices, ASPIRE RF and ASPIRE are valuable trademarks of Cooper Industries in the U.S. and other countries. You
are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.
| w w w . c o r e l i g h t i n g c o n t r o l s . c o m