Product Brochure
Device Configuration Parameters
Cooper Z-Wave devices can be configured to operate in various ways.
The configuration parameters are shown for each configurable device.
RF9501 Light Switch
Parameter
Description
Value Range
1
Delayed Off
* 0 to 127
-128 to -1
2
Panic On Time
* 0 to 127
-128 to -1
3
Panic Off Time
* 0 to 127
-128 to -1
4**
Basic Set Value
* 0 to 127
-128 to -1
5
Power Up State
1=OFF 2= ON
3 = Last State
6
Panic Mode Enable
0=Off_1=On
7
Not Used
Not Used
RF9517 Remote Switch
Parameter
Description
Value
1
Delayed Off
* 0 to 127
-128 to -1
2
Panic On Time
Not Used
3
Panic Off Time
Not Used
4**
Basic Set Value
** 0 to 127
-128 to -1
5
Power Up State
Not Used
6
Panic Mode Enable
Not Used
7
Not Used
Not Used
RF9542-Z Remote Dimmer Accessory
Parameter
Description
Value
1
Delayed Off
* 0 to 127
-128 to -1
2
Panic On Time
Not Used
3
Panic Off Time
Not Used
4**
Basic Set Value
* 0 to 127
-128 to -1
5
Power Up State
1=OFF 2= ON
3 = Last State
6
Panic Mode Enable
0=Off 1=On
7
Dimmer Ramp Time
* 0 to 127
-128 to -1
*The configuration value is a signed single byte number This value
may represent a value with no units or may represent a value such as
time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to
-1 (negative decimal numbers) represents 128 to 255 seconds as
calculated by this formula:
config value = desired time in seconds (or dedsired value) – 256
For an example of 172 seconds: config value = 172 – 256 = -84
(decimal) or 0xAC (hex)
For Parameter 4, this value is the value that will be sent in a Basic Set
command as a result from association to another device.
RF9534, RF9534-N, RF9535-N, RF9536, RF9536-N,
and RF9537-N Dimmers
Parameter
Description
Value
1
Delayed Off
* 0 to 127
-128 to -1
2
Panic On Time
* 0 to 127
-128 to -1
3
Panic Off Time
* 0 to 127
-128 to -1
4**
Basic Set Value
* 0 to 127
-128 to -1
5
Power Up State
1=OFF 2= ON
3 = Last State
6
Panic Mode Enable
0=Off_1=On
7
Dimmer Ramp Time
* 0 to 127
-128 to -1
RF9518 Light Switch
Parameter
Description
Value Range
1
Delayed Off
0 to 127
-128 to -1
2
Panic On Time
0 to 127
-128 to -1
3
Panic Off Time
0 to 127
-128 to -1
4**
Basic Set Value
* 0 to 127
-128 to -1
5
Power Up State
1=OFF 2= ON
3 = Last State
6
Panic Mode Enable
0=Off_1=On
7
Not Used
Not Used
RF9505, RF9505-T Receptacle
Parameter
Description
Value Range
1
Delayed Off
Not Used
2
Panic On Time
* 0 to 127
-128 to -1
3
Panic Off Time
* 0 to 127
-128 to -1
4**
Not Used
Not Used
5
Power Up State
1=OFF 2= ON
3 = Last State
6
Panic Mode Enable
0=Off_1=On
7
Not Used
Not Used
**Not available in earlier versions of the device. Call Cooper