EZ800/EZD Control Commands
MN05013001E128
Block transfer function blocks BT01 .. BT32
Telegram structure
Table 61: Operand overview
Byte Meaning
Value (hex), sent by
Master Slave
0 Toggle byte J page 94 J page 94
1 Command:
Read 92
Write B2
Response:
Read successful C2
Write successful C1
Command rejected C0
2Type 26 26
3 Instance 01 – 20 01 – 20
4 Index J Table 61 J Table 61
5 – 8 Data 1 – 4
Read operation 00 depending on index,
J Table 62, 63
Write operation depending on index,
J Table 62, 63
00
Index
(hex)
Operand Read Write
00 Bit IO, J Table 62 ×
01 Mode, J Table 63 ×
02 Source range 1 I1 × c
1
03 Target range 2 I2 × c
1
04 Number of elements to compare: max. 192
bytes
NO × c
1
1) The value can only be written if it is assigned to a constant in the program.