Sheet 02
Power Xpert Monitoring Software
Custom Ethernet-Enabled Software Monitoring
046
Custom Ethernet-Enabled
Software Monitoring of IT and
Facility Power Equipment
General Description
Using Web servers all connected
through your enterprises network to
Ethernet switches, Data Acquisition
Terminals and Data Acquisition
Engines PXS Foreseer can communi-
cate directly with Power Xpert devices
(i.e., PX Meters, PX Gateways and PX
Gateway Cards), as well as those third-
party devices communicating via
our multi-vendor device drivers to
perform 24-hour, 7 days a week, and
365 days a year monitoring of every
communicating point on your power
system network.
Connectivity Components
Power Xpert devices
PX Meter 4000/6000/8000
PX Gateway 400/600
PX Gateway Cards 1000/2000
PowerVision Server
SNMP connector
Modbus TCP connector
Third-party device drivers
Options
N-Class System (up to 3000 points)
D-Class System (up to 12,000 points)
E-Class System (25,000 – 250,000
points)
Note: All three class systems have available
an editing package for editing and creating
Web views, but only the Class D and E allow
for a redundant server.
Communication Interfaces
Web-browser
Ethernet TCP/IP
Modbus TCP
HTTP
SNMP
XML/SOAP
Power Monitoring Applications
Real-time viewing of power/energy
readings
View trended power/energy
readings
User-defined events
E-mail notification
Instantly trend and graph utility
information from multiple locations
Installation Applications
Low Voltage Switchgear
Medium Voltage Switchgear
Low Voltage Motor Control Centers
Medium Voltage Motor Starters
1-phase and 3-phase UPSs & PDUs
CRAC units
Standby Generators
Communications Applications
Building Management System
(BMS)
HMI
Energy Management Systems
Figure 2.5-4. Power Xpert Software Foreseer Class Application
Data Ac
q
uisition Termina
l
(DAT)
The DAT has 16 di
g
ital
in
p
uts for exam
p
le:
Generator, Buildin
g
Alarm,
Fire Alarm contacts
,
etc
.
A DAE basically captures
information from a N-Class
S
y
stem where there is no
l
oca
l
mon
i
tor
i
n
g
an
d
sen
d
s
i
t
to
t
h
e
ce
n
t
r
a
l M
O
M
se
rv
e
r
.
DA
E
Foreseer Central Mana
g
er
of Managers (MOM)
A
D
A
T
A
A
Web Browser
Client
COMPUTER ROOM A/C
GENE
R
AT
OR
POWER
COMPUT
ER
R
OOM
PO
WER
A
B
B
B
B
B
B
Foreseer Class
Software
Computer
Server
UPS
STS
PD
U
CRA
C
A
TS
B
Generator
Chiller
Rack
C
oo
l-
in
g
A
C
C
D
Legend — Foreseer
Class Connectivity Components
A
B
C
D
Ethernet
Serial
Data Acquisition Engine
(DAE)