9.3
Metering Devices, Protective Relays, Software and Connectivity
Metering Devices
Product Selection
IQ 35M Current Transformers
Accessories
IQ 35M Accessories
Note: Specifications are subject to change without notice and represent
the maximum capabilities of the product with all options installed. This is
not a complete feature list. Features and functionality may vary
depending on selected options, firmware version and product model.
Please refer to User Manual for detailed specifications.
Description
Catalog
Number
Solid Core
IQ35M CT, solid core, 5A:0.33 Vac, 0.30 inch IQ35M-SO-030-5
IQ35M CT, solid core, 20A:0.33 Vac, 0.30 inch IQ35M-SO-030-20
IQ35M CT, solid core, 50A:0.33 Vac, 0.50 inch IQ35M-SO-050-50
IQ35M CT, solid core, 50A:0.33 Vac, 0.75 inch IQ35M-SO-075-50
IQ35M CT, solid core, 100A:0.33 Vac, 1.25 inch IQ35M-SO-125-100
IQ35M CT, solid core, 200A:0.33 Vac, 1.25 inch IQ35M-SO-125-200
IQ35M CT, solid core, 250A:0.33 Vac, 1.25 inch IQ35M-SO-125-250
IQ35M CT, solid core, 300A:0.33 Vac, 1.25 inch IQ35M-SO-125-300
IQ35M CT, solid core, 400A:0.33 Vac, 1.25 inch IQ35M-SO-125-400
Split Core
IQ35M CT, split core, 5A:0.33 Vac, 0.75 inch IQ35M-SP-075-5
IQ35M CT, split core, 30A:0.33 Vac, 0.75 inch IQ35M-SP-075-30
IQ35M CT, split core, 50A:0.33 Vac, 0.75 inch IQ35M-SP-075-50
IQ35M CT, split core, 100A:0.33 Vac, 0.75 inch IQ35M-SP-075-100
IQ35M CT, split core, 200A:0.33 Vac, 0.75 inch IQ35M-SP-075-200
IQ35M CT, split core, 250A:0.33 Vac, 1.25 inch IQ35M-SP-125-250
IQ35M CT, split core, 300A:0.33 Vac, 1.25 inch IQ35M-SP-125-300
IQ35M CT, split core, 400A:0.33 Vac, 1.25 inch IQ35M-SP-125-400
IQ35M CT, split core, 600A:0.33 Vac, 1.25 inch IQ35M-SP-125-600
IQ35M CT, split core, 800A:0.33 Vac, 2.50 inch IQ35M-SP-253-800
IQ35M CT, split core, 1000A:0.33 Vac, 2.50 inch IQ35M-SP-255-1000
IQ35M CT, split core, 1200A:0.33 Vac, 2.50 inch IQ35M-SP-255-1200
IQ35M CT, split core, 1600A:0.33 Vac, 2.50 inch IQ35M-SP-255-1600
IQ35M CT, split core, 2000A:0.33 Vac, 2.50 inch IQ35M-SP-255-2000
IQ35M CT, split core, 2400A:0.33 Vac, 2.50 inch IQ35M-SP-255-2400
Description
Catalog
Number
IQ35M enclosure, NEMA 4X IQ35M-ENC
IQ35M fuse pack, single, 1/2A slow-blow IQ35M-FP1
IQ35M fuse pack, double, 1/2A slow-blow IQ35M-FP2
IQ35M fuse pack, triple, 1/2A slow-blow IQ35M-FP3
IQ35M replacement mounting clips IQ35M-RMC
IQ35M DIN rail IQ35M-DR
IQ35M DIN rail stop clips (10 pack) IQ35M-DRSC
Technical Data and Specifications
●
Voltage input
UL: 90V (L-N) to 600V (L-L)
CE: 90V (L-N) to 300V (L-L)
●
Current input
Scaling: 5–32,767A
Input range: 0–0.333V or
0–1V (selectable)
●
Control power
UL: 90V (L-N) to 600V (L-L)
CE: 90V (L-N) to 300V (L-L)
Accuracy
●
Real power and energy
0.5% (ANSI C12.20, IEC 62053-22 Class 0.5S)
Outputs
●
IQ35MAx1 thru 3:
Real energy pulse: NO static; alarm contacts: NC static
●
IQ35MA11
Reactive energy pulse 30 Vac/Vdc
●
IQ35MAx2, IQ35MAx3
RS-485 two-wire Modbus RTU
●
IQ35MA15 RS-485 two-wire BACnet MS/TP
Inputs
●
IQ35MA15
Two pulse accumulators
Mechanical
●
Mounting
DIN rail or 3-point screwmount
Environmental
●
Operating temperature range
Meter: –30° to 70°C (–22° to 158°F)
Display: –10° to 50°C (14° to 122°F)
●
Storage temperature range
Meter: –40° to 85°C (–40° to 185°F)
Display: –10° to 60°C (14° to 140°F)
●
Humidity range
<95% RH noncondensing
Data Outputs
●
kW, kWh: Total
●
Current: Three-phase average and per phase
●
Voltage: Three-phase average, per phase, and line-line and
line-neutral
●
Power: Real, reactive and apparent;
Three-phase total and per phase
●
Power factor: Three-phase average and per phase
●
Frequency
●
Power demand: most recent and peak
●
Demand configuration: fixed, rolling block and external sync
●
Data logging (IQ35MAx3)
10 configurable data buffers;
configurable demand subinterval (when set at a 15-minute
interval, buffers store data for 60 days)
●
Data logging (IQ35MA15)
6 configurable data buffers;
configurable demand subinterval (when set at a 15-minute
interval, buffers store data for 60 days)
●
Trending requires communication network to retrieve data