Metering Devices, Protective Relays, Software and Connectivity
Connectivity Options
Breaker Interface Module II (BIM II)
Contents
Description Page
Power Xpert Gateways . . . . . . . . . . . . . . . . . . . . . . V3-T9-259
Power Xpert Ethernet Switches . . . . . . . . . . . . . . . V3-T9-272
Power Xpert Gateway
Series 1000 Card—Power Distribution Unit . . . . . . V3-T9-276
Power Xpert Gateway
Series 2000 Card—Uninterruptible Power Supplies V3-T9-279
mMINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-282
MINTII RS-232 Converter. . . . . . . . . . . . . . . . . . . . V3-T9-284
IPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-285
DPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-286
MPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-287
I/O Devices Digital Input Module (DIM) . . . . . . . . . V3-T9-288
Addressable Relay II. . . . . . . . . . . . . . . . . . . . . . . . V3-T9-290
Breaker Interface Module II (BIM II)
Features, Benefits and Functions . . . . . . . . . . . V3-T9-294
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V3-T9-295
Technical Data and Specifications . . . . . . . . . . . V3-T9-295
Sub-Network Master Local Display (SMLD) . . . . . . V3-T9-297
IMPCABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-299
Breaker Interface Module II (BIM II)
Product Description
Eaton’s Breaker Interface
Module is a panel-mounted
device that displays the
following parameters.
●
Phase current
●
Energy
●
Present demand watts
●
Peak demand watts
●
Average demand current
●
Cause and magnitude
of trip
●
Trip history
●
% Total Harmonic
Distortion (THD) for
each phase
●
% Harmonic Content for
each phase (1st–27th
harmonic)
●
Custom circuit description
Note: The Breaker Interface
Module displays only a portion of
the information it receives from
the Digitrip RMS 910, 1150 and
Power Sentinels. The balance of
the information (such as
Waveform Analysis and Power
Factor) can be passed through the
unit to a master computer, where
it can be viewed.
Application Description
●
810, 910, 750, 1050, 550,
1150, 520MC, IQ Energy
Sentinels and Power
Sentinels
●
Event logging
●
Alarming
●
High load indication
●
Peak exceeded alarm
●
Grouping of meters
An operator can use the
Breaker Interface Module to:
●
Complete Initial System
Setup:
●
Select system
frequency (50/60 Hz)
●
Set password
●
Configure OPTIM
Protective Settings.
●
Select protection
options
●
Select alarm levels
●
Display Information:
●
Metered values
●
Trip event information
●
Breaker information
●
Time-current set points
●
Te s t OP T I M Tr i p Un i t
Performance:
●
Phase and ground
●
Trip/no trip
●
Expanded Energy
Monitoring:
●
Set addresses for group
energy monitoring
●
Group energy readings
●
Local and Remote
Indication:
●
Remote indication/
alarming
●
Breaker status LED
indication
●
Expanded
Communications:
●
Communicate with:
– OPTIM Trip Units
– Digitrip RMS 810, 910
a n d 115 0 Tr i p Un i t s
– IQ Energy Sentinels
and Universal IQ
Energy Sentinels
– A total of 50 devices