User`s guide

V3-T9-288 Volume 3—Power Distribution and Control Assemblies CA08100004E—November 2013 www.eaton.com
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9.5
Metering Devices, Protective Relays, Software and Connectivity
Connectivity Options
Digital Input Module (DIM)
Contents
Description Page
Power Xpert Gateways. . . . . . . . . . . . . . . . . . . . . . V3-T9-259
Power Xpert Ethernet Switches . . . . . . . . . . . . . . . V3-T9-272
Power Xpert Gateway
Series 1000 Card—Power Distribution Unit . . . . . . V3-T9-276
Power Xpert Gateway
Series 2000 Card—Uninterruptible Power Supplies V3-T9-279
mMINT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-282
MINTII RS-232 Converter . . . . . . . . . . . . . . . . . . . V3-T9-284
IPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-285
DPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-286
MPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-287
I/O Devices Digital Input Module (DIM)
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V3-T9-289
Technical Data and Specifications . . . . . . . . . . . V3-T9-289
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-289
Addressable Relay II . . . . . . . . . . . . . . . . . . . . . . . V3-T9-290
Breaker Interface Module II (BIM II) . . . . . . . . . . . V3-T9-293
Sub-Network Master Local Display (SMLD). . . . . . V3-T9-297
IMPCABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-299
I/O Devices Digital Input Module (DIM)
Product Description
Eaton’s Digital Input Module
is a device that interfaces
with up to four standard utility
(electric, gas, water) meters
or monitors eight digital
inputs. It translates KYZ
pulses from meters into a
register count that is
maintained and compiled
within the DIM module in
non-volatile memory. The
pulse count can be accessed
from the DIM module
remotely using Eaton Power
Management Software,
including the Energy Billing
application.
The DIM can also be used to
monitor eight digital inputs
from switch closures.
Features, Benefits and
Functions
Reads four separate KYZ
equipped utility meters
Pulse counts stored in non-
volatile memory
Each channel
independently monitors
KYZ counts, pulse counts,
or digital indications
Monitors a maximum of
eight individual digital
inputs
Input channels are isolated
Isolated 24 Vdc power
is provided on the I/O
connector
LED indicators on the input
channels indicate when the
unit is counting
10 LED status indicators,
100 ohm termination DIP
switch, address selector
switches
DIN rail mounting
Standards and Certifications
UL 873
CE mark (48 Vdc operation)
FCC Part 15, Class A
IEC 1000-4-x
CISPR 22, Class A
IEC 1000-4-2; 1995, Electro
Static Discharge
IEC 1000-4-3; 1995,
Radiated RF Immunity
IEC 1000-4-6; 1996,
Conducted RF Immunity
FCC Part 15 Class A
(10 meters) Radiated
Emissions
CISPR 22, Class A
(30 meters); 1991,
Radiated Emissions
CISPR 22, Class A; 1991,
Conducted Emissions
(PowerPort)