9.5
Metering Devices, Protective Relays, Software and Connectivity
Connectivity Options
Power Xpert Gateways
Contents
Description Page
Power Xpert Gateways
Product Selection Guide . . . . . . . . . . . . . . . . . . V3-T9-260
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-266
Standards and Certifications . . . . . . . . . . . . . . . V3-T9-267
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V3-T9-267
Technical Data and Specifications . . . . . . . . . . . V3-T9-268
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-271
Power Xpert Ethernet Switches . . . . . . . . . . . . . . . V3-T9-272
Power Xpert Gateway
Series 1000 Card—Power Distribution Unit . . . . . . V3-T9-276
Power Xpert Gateway
Series 2000 Card—Uninterruptible Power Supplies V3-T9-279
mMINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-282
MINTII RS-232 Converter. . . . . . . . . . . . . . . . . . . . V3-T9-284
IPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-285
DPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-286
MPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-287
I/O Devices Digital Input Module (DIM) . . . . . . . . . V3-T9-288
Addressable Relay II. . . . . . . . . . . . . . . . . . . . . . . . V3-T9-290
Breaker Interface Module II (BIM II) . . . . . . . . . . . V3-T9-293
Sub-Network Master Local Display (SMLD) . . . . . . V3-T9-297
IMPCABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-299
Power Xpert Gateways
Product Description
The Power Xpert Gateway
400/600 is typically installed
in an electrical assembly—
a motor control center, low/
medium voltage switchgear
or switchboard to consolidate
data available from
components such as trip units,
meters, motor controllers and
protective relays.
Power Xpert Gateways
provide a cost-effective
method to easily Web-enable
Eaton and third-party products.
The Gateway consists of an
embedded Web server that
allows the user to connect
to Eaton products such as
breakers, meters and relays
found in MCCs, LV and MV
Switchgear and switchboards
—to name a few—that
communicate via Eaton
protocols INCOM and
QCPort, in addition to
third-party products that
communicate via Modbus
RTU. The Gateway provides
the central connection point
for the power metering/
monitoring/protective
devices, allowing their
parameters to be
monitored via the Web.
Power Xpert Gateways
provide data communications
to Eaton’s Power Xpert
Software to facilitate
centralizing and gathering data
for long-term data archival,
analysis and trending features.
The PXG is compatible with
and facilitates integration
with many third-party building
and factory automation
systems via Modbus TCP
and Web Services.
The PXG600 allows you
to enable pre-selected
parameters to be trended
for each supported device.
Selecting the trend symbol
will generate a real-time graph
for that parameter and can be
viewed for the past 24 hours,
seven days, 30 days or all
past history.
The PXG600 also offers direct
e-mail notifications to up to
10 users. Select from event
notifications, data logs, event
logs and heartbeat e-mails.
Information is presented in
organized, user-friendly Web
pages and includes, but is not
limited to, the following:
Device status
Comm status
Voltage
Current
Power
Power factor
Energy
Power quality
Temp erature
I/O states
Power Xpert Gateway
Screenshots
Home Page
Main Page
Bus Page
Device Page
Trending Page (PXG600 Only)