User`s guide

V3-T9-230 Volume 3—Power Distribution and Control Assemblies CA08100004E—November 2013 www.eaton.com
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9.4
Metering Devices, Protective Relays, Software and Connectivity
Protective Relays
Technical Data and Specifications
Climatic Environmental
Conditions
Storage temperature:
–13°F to 158°F (–25°C up
to +70°C)
Operating temperature:
–4°F to 140°F (–20°C up
to +60°C)
Permissible humidity at
ann. average: <75% rel.
(on 56d up to 95% rel.)
Permissible Installation
altitude:
<2000m (6561.67 ft)
above sea level
If 4000m (13,123.35 ft)
altitude apply, a changed
classification of the
operating and test
voltages may be
necessary
Degree of Protection EN 60529
HMI front panel with
seal: IP54
Rear side terminals: IP30
Routine Test
Insulation test according to
IEC 60255-5: All tests to be
carried out against ground
and other input and output
circuits
Aux. voltage supply, digital
inputs, current measuring
inputs, signal relay outputs:
2.5 kV (eff)/50 Hz
Voltage measuring inputs:
3.0 kV (eff)/50 Hz
All wire-bound
communication interfaces:
1. 5 k V D C
Housing
Material, housing:
aluminum extruded section
Material, front panel:
aluminum/foil front
Mounting position:
horizontal (±45° around the
X-axis must be permitted)
Plug-in Connector with
Integrated Short-Circuiter
(Conventional Current Inputs)
Nominal current:
1A and 5A
Continuous loading
capacity: 4 x I
n
/
continuously
Overcurrent withstand:
30 x I
n
/10s
100 x I
n
/1s
250 x I
n
/10 ms
(1 half-wave)
Screws: M4, captive type
according to VDEW
Connection cross-sections:
2 x 2.5 mm
2
(2 x AWG
14) with wire end ferrule
1 x or 2 x 4.0 mm
2
(2 x AWG 12) with
ring cable sleeve or
cable sleeve
1 x or 2 x 6 mm
2
(2 x AWG 10) with
ring cable sleeve or
cable sleeve
Voltage Supply
Aux. voltage: 19–300 Vdc/
40–250 Vac
Buffer time in case of
supply failure: >= 50 ms
at minimal aux. voltage
communication is
permitted to be interrupted
Max. permissible making
current:
18A peak value for
<0.25 ms
12A peak value for
<1 ms
The voltage supply must
be protected by a fuse of:
2.5A time-lag miniature
fuse 5 x 20 mm (approx.
1/5 in. x 0.8 in.) according
to IEC 60127
3.5A time-lag miniature
fuse 6. 3 x 32 mm
(approx. 1/4 in. x
1 1/4 in.) according
to UL 248-14
Power Consumption
Power supply range: Power
consumption in idle mode
Max. power consumption
19–300 Vdc: 6W 8.5W
40–250 Vac
For frequencies of
40–70 Hz: 6W 8.5W
Real-Time Clock
Running reserve of the
real-time clock: 1 year min
Display
Display type: LCD with
LED background
illumination
Resolution graphics
display: 128 x 64 pixel
LED-type: two colored,
red/green
Number of LEDs, housing
B1: 8
Digital Inputs
Max. input voltage:
300 Vdc/270 Vac
Input current: <4 mA
Reaction time: <20 ms
Fallback time: <30 ms (safe
state of the digital inputs)
Four switching thresholds:
Un = 24 Vdc, 48 Vdc,
60 Vdc, 110 Vac/dc,
230 Vac/Vdc Un = 24 Vdc
Switching threshold
1 ON
Switching threshold 1
OFF
Min. 19.2 Vdc
Max. 9.6 Vdc
Un = 48 V/60 Vdc
Switching threshold
2 ON
Switching threshold 2
OFF
Min. 42.6 Vdc
Max. 21.3 Vdc
Un = 110/120 Vac/dc
Switching threshold
3 ON
Switching threshold 3
OFF
Min. 88.0 Vdc/
88.0 Vac
Max. 44.0 Vdc/
44.0 Vac
Un = 230/240 Vac/Vdc
Switching threshold
4 ON
Switching threshold 4
OFF
–Min. 184 Vdc/
184 Vac
Max. 92 Vdc/92 Vac
Terminals: screw-type
terminal