Metering Devices, Protective Relays, Software and Connectivity
Protective Relays
Features, Benefits and Functions
Complete protection,
metering and control in
a single compact case to
reduce panel space,
wiring and costs
Flexible current, voltage
and frequency protection
and programmability to
cover a broad range of
applications while
simplifying relay ordering
and reducing inventory
Integral test function
reduces maintenance
time and expense
Relay self-diagnostics and
reporting improves uptime
and troubleshooting
Breaker trip circuit
monitoring improves the
reliability of the breaker
operation
Programmable LEDs and
logic control features that
can replace and eliminate
external auxiliary relays,
timers, light and wiring
Zone selective interlocking
improves coordination and
tripping times and saves
money compared to a
traditional bus differential
scheme
Trip and event recording
in non-volatile memory
provides detailed
information for analysis
and system restoration
256 cycles of waveform
capture aids in post fault
analysis (viewable using
PowerNet and
NPWAVEFORM
component
Front RS-232 port and
PowerPort software
provides local computer
access and a user-friendly,
Windows-based interface
for relay settings, and
configuration and data
retrieval
Drawout case design
for quick and easy relay
removal and replacement
Breaker open/close
control from relay
faceplate or remotely
via communications
Remote communications
to Eaton PowerNet
monitoring system or PC
Free PowerPort utility
software for local PC
interface to the FP-6000 for
relay settings, monitoring
and control
The protection functions are
listed below and shown on
Page V3-T9-168.
The FP-6000 provides phase
overcurrent (forward, reverse
or both):
Two-stage instantaneous
with timers (50P-1 and
50P-2)
Inverse time overcurrent
(51P)
Directional control (67P)
10 standard curves
Instantaneous or time
delay reset
Voltage restrained inverse
time overcurrent (51P2)
The FP-6000 provides two
ground overcurrent elements,
one measured (IX) and one
calculated (IR):
Independent measured
ground or neutral
directional overcurrent
elements:
Two-stage
instantaneous with
timers (50X-1 and 50X-2)
Inverse time overcurrent
(51X)
Ground directional
polarizing (67N) -3vo and
negative sequence
10 standard curves
Instantaneous or time
delay reset
Independent calculated
ground or neutral
directional overcurrent
elements:
Two-stage
instantaneous with
timers (50R-1 and
50R-2)
Inverse time overcurrent
(51R)
Ground directional
polarizing (67N) –3vo,
I pol and negative
sequence
10 standard curves
Instantaneous or time
delay reset
The FP-6000 also provides
the following protective
features:
Breaker failure (50BF)
Phase unbalance negative
sequence overcurrent
(46-1, 46-2)
Phase voltage unbalance
and sequence protection
(47-1, 47-2)
Main 3-phase under/
overvoltage (27M-1,
27M-2, 59M-1, 59M-2)
Under/overfrequency
(81U-1, 81U-2, 81O-1,
81O-2)
Auxiliary single-phase
under/overvoltage (27A-1,
27A-2, 59A-1, 59A-2)
Neutral voltage (59N-1,
59N-2)
Apparent and
displacement power factor
(55A, 55D)
Forward/reverse power
protection (32-1, 32-2,
32-3)
Forward/reverse VAR
protection (32V-1, 32V-2,
32V-3)
Thermal Protection (49DT,
49MT, 49DA, 49MA)
Sync check (25)
Zone interlocking for bus
protection (87B). The
FP-6000 feeder relay
includes a zone selective
interlocking feature that can
be used with other Eaton
devices like the Digitrip
3000 overcurrent relay
The FP-6000 provides the
following metering functions:
Amperes (rms, phasor
and sequence)
Amperes demand and
peak demand.
Volts (rms, phasor and
sequence).
VA and VA demand
Watts and kW demand and
peak demand.
Forward/reverse/net kWh
Vars and kVAR demand
and peak demand
Lead/lag/net kVARh
Power factor
Frequency
Voltage and current %THD
and magnitude THD
RTD
Minimum/maximum
recording with date/
time stamp
Trending (load profile
over time)
The FP-6000 provides the
following monitoring and data
recording functions that
enhance the security of the
protection system and
provides useful information
for scheduling maintenance:
Trip circuit monitoring
Breaker wear (accumulated
interrupted current)
Waveform capture
(256 cycles total, up to
16 events)
Fault data logs (up to
16 events).
Sequence of events report
(up to 100 events)
Clock (1ms stamping)
The FP-6000 provides
standard control functions
plus userconfigurable custom
control capabilities. This logic
can be used for applications
such as main-tie-main
transfer schemes.
Remote open/close.
Optional local open/close
Programmable I/O
Programmable logic gates
and timers
Multiple setting groups
(up to four)
Bus transfer logic
Cold load pickup
Loss of potential
(PT blown fuses)
Autoreclose Function (79)
Auto Zone Coordination
The FP-6000 supports the
following communication
options:
Local HMI
Password protected
Addressable
Front RS-232 port
Rear RS-485 port
Rear FSK port
Protocols:
INCOM
Modbus RTU