Product Brochure

www.eaton.com
www.arrowhart.com
P-1
EATON 2014 Arrow Hart Buyers Guide
P
SECTION
Commercial specification grade occupancy sensors features
•
SelectableautomaticONmodeormanualONmode
•
Convenientinstallationandtestmodeforsetup
•
Adjustablebuilt-inlightlevelsensor
•
Selectabletimedelay
•
CaliforniaTitle24compliant
•
Forusewithincandescentlamps,halogenfixtures,
electronicandmagneticfluorescentballasts,
andelectricalmotorloads
•
WallplateincludedwithOSP10&OSD10models
•
120Vand277Vinthesameunit
•
Single-poleor3-waywiring
•
ManualOFFpushbuttoncanbeusedin
eitherautomaticormanualmode
•
Reinforcedlensistamper-resistant
•
Zero-crossingtechnologytomaximizerelaylife
andensurewallswitchlongevity
•
Fitsstandardsizedecoratorwallplate
Electronic Specifications Coverage area
Wire leads – wall mount PIR with instinct (no neutral)
Coverage area Description Color suffix Catalog no.
1000 sq. ft. major motion (92.2 sq. m)
300 sq. ft. minor motion (27.9 sq. m)
180º passive infrared single relay occupancy
sensing wall switch
A, BK, GY, LA, V, W OSP10-__
180º passive infrared dual relay occupancy
sensing wall switch
A, BK, GY, LA, V, W OSP10D-__
cULus listed
Wire leads – wall mount PIR (no neutral)
Coverage area Description Color suffix Catalog no.
1000 sq. ft. major motion (92.2 sq. m)
300 sq. ft. minor motion (27.9 sq. m)
180º passive infrared single relay occupancy
sensing wall switch
A, BK, GY, LA, V, W OSP10M-__
cULus listed
Wire leads – wall mount dual tech with instinct
(neutral required)
Coverage area Description Color suffix Catalog no.
1000 sq. ft. major motion (92.2 sq. m)
300 sq. ft. minor motion (27.9 sq. m)
180º dual tech single relay occupancy sensing
wall switch
A, BK, GY, LA, V, W OSD10N-__
180º dual tech dual relay occupancy sensing
wall switch
A, BK, GY, LA, V, W OSD10DN-__
cULus listed
3.13"
(79mm)
4.88"
(133mm)
OSP10
3.28"
(83.31mm)
1.80"
(45.72mm)
"
3.2
8
)
83.31
mm
1.80
45.72
mm
3.81"
(96.77mm)
OSP10M
3.13"
(79mm)
4.88"
(133mm)
OSD10DN
Testing & code compliance: ListedtoUL508(UL244AforOSP10M),CaliforniaTitle24EnergyCodecompliant,RoHSCompliant
Material characteristics:FlammabilitymeetsUL94requirements;V0rated,TemperatureRating:0ºCto40ºC(32ºFto104ºF)
Compliances, specifications and availability are subject to change without notice.
Color ordering information:
For ordering devices, include Catalog no. followed by the Color suffix: A (Almond), BK (Black), GY (Gray), LA (Light Almond),
V (Ivory), W (White)
A BK GY LA V W
(Almond) (Black) (Gray) (Lt. Almond) (Ivory) (White)
Commercial occupancy sensors
Wire leads-wall mount
OSP10, OSP10D, OSD10N, OSD10DN OSP10M
Power requirements:
120/277VAC @ 60Hz
Power requirements:
120/277VAC @ 60Hz
Maximum load:
Incandescent/halogen:
@120V: 6.7A, 800W, 60Hz
Fluorescent:
@120V: 10A, 1200W, 60Hz
@277V: 9.8A, 2700W, 60Hz
Motor:
@120V: 1/4 HP @125 V/AC
Maximum load:
Incandescent/halogen:
@120VAC, 60Hz: 15A, 1800W
Magnetic ballast (Fluorescent, MLV):
@120VAC, 60Hz: 15A, 1800VA
@277VAC, 60Hz: 8A, 2200VA
Electronic ballast
(Fluorescent, CFL/LED/ELV lighting):
@120VAC, 60Hz: 10A, 1200VA
@277VAC, 60Hz: 8A, 2200VA
Motor:
@120VAC, 60Hz; 1/2 Hp
Minor
Motion, IR
Major
Motion, IR
Maximum coverage area may
vary somewhat according to room
shape and the presence of obstacles.
36’
8’
20’
15’
8’

Summary of content (1 pages)