Specification
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com TD.31F.01.T.E
Technical Data
Page 20 Effective: October 2001
Meter Breakers
Technical Data and Speciļ¬cations
Typical Wiring Diagrams (Type CH Style House Panels)
Figure 44. Type CH Wiring Diagram 1
Figure 45. Type CH Wiring Diagram 2
Figure 46. Type CH Wiring Diagram 3
Figure 47. Type CH Wiring Diagram 4
Figure 48. Type CH Wiring Diagram 5
Figure 49. Type CH Wiring Diagram 6
Figure 50. Type CH Wiring Diagram 7
Figure 51. Type CH Wiring Diagram 8
Type CH Wiring Diagram Key
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CHB
(OPTIONAL)
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE BW
(OPTIONAL)
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19
20
23
21
25
22
27
24
29
26
31
28
33
30
35
32
37
34
39
36
41
38
40
42
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CHB
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19 20
21 22
23 24
25 26
27
28
29 30
31 32
33 34
35 36
37 38
39
40
41 42
(OPTIONAL)
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE BW
(OPTIONAL)
(OPTIONAL)
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CH
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE CSR
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19 20
21 22
23 24
25 26
27
28
29 30
31 32
33 34
35 36
37 38
39
40
41 42
(OPTIONAL)
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19
20
23
21
25
22
27
24
29
26
31
28
33
30
35
32
37
34
39
36
41
38
40
42
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CH
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
N B
LINE
(OPTIONAL)
#14-6 AWG
#14-1/0 AWG
#6 AWG - 250 kcmil
#1 AWG - 300 kcmil