Specifications
February 2007
CA08101001E For more information visit: www.eaton.com
16-65
Transfer Switches
16
Transfer Switch Equipment
Magnum Closed Transition Soft Load Transfer Switch with ATC 5000 Controller
Magnum Closed Transition Soft
Load Transfer Switches with
ATC 5000 Controller (Continued)
Product Selection
Transfer Switch Catalog Number
Identification
Transfer switch equipment catalog
numbers provide a significant amount
of relevant information that pertains to
a particular piece of equipment. The
catalog number identification table
(Table 16-55) provides the required
interpretation information. An example
for an open transition switch is offered
to initially simplify the process.
Example: Catalog Number (circled
numbers correspond to position
headings in Table 16-55).
The catalog number CTVCMGE32000XRU
describes a Soft Load ATS with the
drawout switching devices mounted
vertically in the enclosure. The intelli-
gence, represented by the ATC-5000, is
a microprocessor-based logic package.
The Magnum Breaker is used as the
switching device and is a 3-pole
molded case breaker for each source.
The continuous current rating of this
equipment is 2000 A and is applicable
at 480/277 Vac, 60 Hz. The transfer
switch equipment is enclosed in a
NEMA 3R enclosure and is listed for
Underwriters Laboratories (UL).
Catalog Numbering System
Table 16-55. Transfer Switch Catalog Number System — Magnum Soft Load Transfer Switches 800 – 3200 Amperes
Using the Catalog Numbering System provides an overview of the ten basic style/feature categories
which generate the 15 digit catalog number.
PCS = Power Case Switch PCB = Power Circuit Breaker
BOCA is a registered trademark of Building Officials
and Code Administrators International, Inc. Cutler-
Hammer is a federally registered trademark of Eaton
Corporation. CSA is a registered trademark of the
Canadian Standards Association. Gen-Tran is a regis-
tered trademark of Gen-Tran Corporation. ISO is the
registered trademark and sole property of the Interna-
tional Organization for Standardization. National Elec-
trical Code and NEC are registered trademarks of the
National Fire Protection Association, Quincy, Mass.
NEMA is the registered trademark and service mark of
the National Electrical Manufacturers Association. Uni-
form Building Code (UBC) is a trademark of the Interna-
tional Conference of Building Officials (ICBO). UL and
cUL are federally registered trademark of Underwriters
Laboratories Inc.
CT V C MG E 3 2000 X R U
1to2 3 4 5 6 7 8 9to
12 13 14 15
to
CT V C MG E 3 2000 X R U
Logic
Position 4
C = ATC 5000
Type
Position 1-2
CT = Closed
Transition
Orientation
Position 3
V = Vertical
Frame
Position 5-6
MG = Molded Cases
Magnum DS
Switch
Position 7
A = Fixed Mount,
Power Case Switch
PCS Both
B = Fixed Mount,
Power Case Circuit
Breaker PCB Both
C = Fixed Mount,
PCB Normal,
PCS Emergency
D = Fixed Mount,
PCS Normal,
PCB Emergency
E = Drawout, PCS Both
F = Drawout, PCB Both
G = Drawout, PCB Normal,
PCS Emergency
H = Drawout, PCS Normal,
PCB Emergency
Poles
Position 8
3 = 3 Poles
4 = 4 Poles
Amperes
Position 9-12
0800 = 800 A
1000 = 1000 A
1200 = 1200 A
1600 = 1600 A
2000 = 2000 A
2500 = 2500 A
3200 = 3200 A
Enclosure
Position 14
S = NEMA 1
R = NEMA 3R
Listing
Position 15
U = UL Listed
Voltage
Position 13
A = 120 V 60 Hz 3-Phase 3-Wire
B = 208/120 60 Hz 3-Phase 4-Wire
E = 600 V 60 Hz 3-Phase 3-Wire
E = 600 V 60 Hz 3-Phase 4-Wire
G = 220/127 V 50 Hz 3-Phase 4-Wire
G = 220/110 V 50/60 Hz 1-Phase 3-Wire
H = 380/220 V 50 Hz 3-Phase 4-Wire
K = 600 V 50 Hz 3-Phase 4-Wire
M = 230 V 50 Hz 3-Phase 3-Wire
M = 230 V 50 Hz 1-Phase 3-Wire
N = 401/230 V 50 Hz 3-Phase 4-Wire
O = 415/240 V 50 Hz 3-Phase 4-Wire
W= 240/120 V 60 Hz 1-Phase 3-Wire
W= 240 V 60 Hz 3-Phase 3-Wire
W= 240/120 V 60 Hz 3-Phase 4-Wire Hi-Leg
W= 230/115 V 60 Hz 1-Phase 3-Wire
X = 480 V 60 Hz 3-Phase 3-Wire
X = 480/277 V 60 Hz 3-Phase 4-Wire
X = 480/240 V 50 Hz 1-Phase 2-Wire