Specifications

February 2007
CA08101001E For more information visit:
www.eaton.com
16-5
Transfer Switches
16
Transfer Switch Equipment
Product Selection
Table 16-4. Transfer Switch Product Family (Continued)
Key:
DO = Drawout
FM = Fixed Mounted
MPB = Magnum Power Breaker
MPS = Magnum Power Switch
MCB = Molded Case Breaker
MCS = Molded Case Switch
Description Transfer Switch Equipment Catalog Numbering System
Type
Orientation
Logic Frame Switch Poles Amperes Voltage Enclosure Listing
Automatic Closed
Transition
(<100 ms)
(600 Vac)
(600 – 5000 A)
CT = Closed
Transition
V = Vertical I = ATC-800
Closed Transition
IQ Transfer
Device (Magnum)
MG = 600 – 5000 A
Fixed Mount
A = FM,
N(MPS)
E(MPS)
B = FM,
N(MPB)
E(MPB)
C = FM,
N(MPB)
E(MPS)
D = FM,
N(MPS)
E(MPB)
Drawout Mount
E = DO,
N(MPS)
E(MPS)
F = DO,
N(MPB)
E(MPB)
G = DO,
N(MPB)
E(MPS)
H = DO,
N(MPS)
E(MPB)
2 = 2-Poles
3 = 3-Poles
4 = 4-Poles
(4 Poles –
3000 A
Maximum)
0600 = 600 A
0800 = 800 A
1000 = 1000 A
1200 = 1200 A
1600 = 1600 A
2000 = 2000 A
2500 = 2500 A
3000 = 3000 A
4000 = 4000 A
(600 A FM
Only)
A = 120 V 60 Hz
B = 208 V 60 Hz
E = 600 V 60 Hz
G = 220 V 50/60 Hz
H = 380 V 50 Hz
K = 600 V 50 Hz
M = 230 V 50 Hz
N = 401 V 50 Hz
O = 415 V 50 Hz
W = 240 V 60 Hz
X = 480 V 60 Hz
Z = 365 V 50 Hz
K = Open
S = NEMA 1
R = NEMA 3R
J = NEMA 12
L = NEMA 4
D = NEMA 4X
(J, L and D
65 kAIC, 1200 A
and Below Only)
U = UL 1008 Listed
R = UL Recognized
Z = UL 891 Listed
X = No Listing
Bypass Isolation
(600 Vac)
(800 – 5000 A)
BI = Bypass
Isolation
Refer to
Page 16-24
V = Vertical I = ATC-600 Device (Magnum)
MG = 600 – 5000 A
Drawout Mount
E = DO,
N(MPS)
E(MPS)
F = DO,
N(MPB)
E(MPB)
G = DO,
N(MPB)
E(MPS)
H = DO,
N(MPS)
E(MPB)
2 = 2-Poles
3 = 3-Poles
4 = 4-Poles
(4 Poles –
3000 A
Maximum)
0200 = 200 A
1000 = 1000 A
1200 = 1200 A
1600 = 1600 A
2000 = 2000 A
2500 = 2500 A
3000 = 3000 A
4000 = 4000 A
A = 120 V 60 Hz
B = 208 V 60 Hz
E = 600 V 60 Hz
G = 220 V 50/60 Hz
H = 380 V 50 Hz
K = 600 V 50 Hz
M = 230 V 50 Hz
N = 401 V 50 Hz
O = 415 V 50 Hz
W = 240 V 60 Hz
X = 480 V 60 Hz
Z = 365 V 50 Hz
S = NEMA 1 U = UL 1008 Listed
R = UL Recognized
Z = UL 891 Listed
X = No Listing
Closed Transition
Bypass Isolation
(<100 ms)
(600 Vac)
(800 – 5000 A)
CB = Closed
Transition
Bypass
Isolation
V = Vertical I = ATC-800
Closed Transition
IQ Transfer
Device (Magnum)
MG = 600 – 5000 A
Drawout Mount
E = DO,
N(MPS)
E(MPS)
F = DO,
N(MPB)
E(MPB)
G = DO,
N(MPB)
E(MPS)
H = DO,
N(MPS)
E(MPB)
2 = 2-Poles
3 = 3-Poles
4 = 4-Poles
(4 Poles –
3000 A
Maximum)
0800 = 800 A
1000 = 1000 A
1200 = 1200 A
1600 = 1600 A
2000 = 2000 A
2500 = 2500 A
3000 = 3000 A
4000 = 4000 A
A = 120 V 60 Hz
B = 208 V 60 Hz
E = 600 V 60 Hz
G = 220 V 50/60 Hz
H = 380 V 50 Hz
K = 600 V 50 Hz
M = 230 V 50 Hz
N = 401 V 50 Hz
O = 415 V 50 Hz
W = 240 V 60 Hz
X = 480 V 60 Hz
Z = 365 V 50 Hz
S = NEMA 1 U = UL 1008 Listed
R = UL Recognized
Z = UL 891 Listed
X = No Listing
Closed Transition
Soft Load
(600 Vac)
(800 – 5000 A)
CT = Closed
Transition
Soft Load
Refer to
Page 16-58
V = Vertical C = Soft Load
P = Soft Load
Parallel Source
Device (Magnum)
MG = 600 – 5000 A
Fixed Mount
A = FM,
N(MPS)
E(MPS)
B = FM,
N(MPB)
E(MPB)
C = FM,
N(MPB)
E(MPS)
D = FM,
N(MPS)
E(MPB)
Drawout Mount
E = DO,
N(MPS)
E(MPS)
F = DO,
N(MPB)
E(MPB)
G = DO,
N(MPB)
E(MPS)
H = DO,
N(MPS)
E(MPB)
2 = 2-Poles
3 = 3-Poles
4 = 4-Poles
(4 Poles –
3000 A
Maximum)
0800 = 800 A
1000 = 1000 A
1200 = 1200 A
1600 = 1600 A
2000 = 2000 A
2500 = 2500 A
3000 = 3000 A
4000 = 4000 A
A = 120 V 60 Hz
B = 208 V 60 Hz
E = 600 V 60 Hz
G = 220 V 50/60 Hz
H = 380 V 50 Hz
K = 600 V 50 Hz
M = 230 V 50 Hz
N = 401 V 50 Hz
O = 415 V 50 Hz
W = 240 V 60 Hz
X = 480 V 60 Hz
Z = 365 V 50 Hz
S = NEMA 1
R = NEMA 3R
(NEMA 3R
Walk-In or
Non-Walk-In)
U = UL 1008 Listed
R = UL Recognized
Z = UL 891 Listed
X = No Listing