Specifications

February 2007
16-44
For more information visit: www.eaton.com CA08101001E
Transfer Switches
16
Transfer Switch Equipment
Transfer Switch — Product Selection
Table 16-45. Automatic Transfer Switch Features (Continued)
Consult factory for contactor rating availability.
Ground Fault protection is required for Service Disconnects rated 1000 amperes or more if the electrical service is a solidly grounded wye system of
more than 150 volts to ground but not exceeding 600 volts phase to phase.
Select 16S for Service Entrance rating on RLC1.
S = Standard, O = Optional
Feature
Number
Description Wall-Mount
Product
Floor
Standing
Closed
Transition
Soft
Load
RLC1 ATV1
ATH1
ATC1
ATV3
ATH3
ATC3
ATVI
ATHI
NTHE
NTVE
MTHX
MTVX
ATVIMG BIVIMG CTVIMG CTVCMG
Residential Contactor
Switch ATC-100 Controller
Light Commercial Molded
Case Device and Contactor
Design ATC-100 Controller
Molded Case Switch
ATC-300 Controller
Contactor Switch
ATC-300 Controller
Molded Case Device
ATC-600 IQ Transfer
Non-Automatic
Transfer Switch
Manual
Transfer Switch
Magnum Fixed and
Drawout Mount
ATC-600 IQ Transfer
Magnum
Bypass Isolation
ATC-600 IQ Transfer
Magnum Fixed and
Drawout Mount ATC-800
Closed Transition
Magnum Load Fixed
and Drawout Mount
ATC-5000 Soft Load
32
32A
32B
32C
32D
32E
32F
Delayed Transfer Operation Modes
Time Delay Neutral
Adjustable 0 – 120 Seconds
Load Voltage Decay
Adjustable 2 – 30% Nominal Voltage
In-Phase Monitor Defaults to
Load Voltage Decay
In-Phase Monitor Defaults to
Time Delay Neutral
Delay Transition Timer
Adjustable 3 – 60 Seconds
In-Phase Monitor
S
S
S
O
S
S
O
O
O
S
O
O
O
S
O
O
O
S
O
O
O
34
34A
34C
34E
Logic Extender Cable
48 Inches (1219 mm)
96 Inches (2438 mm)
144 Inches (3658 mm)
O
O
O
O
O
O
35A Pretransfer Signal Contacts 1 Form C SS O O O O O
36 Load Shed from Emergency OOOOO
37
37A
37B
Rated as Suitable for Use as
Service Equipment

(Requires 16B or 16N or 16S)
Without Ground Fault Protection
With Ground Fault Protection
OO
O
O
O
O
O
O
O
O
O
O
O
O
O
38
38A
38B
Stainless Steel Device Covers
SS Cover for Device Plate or
Service Equipment Disconnect
SS Cover for Controller
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
39
39A
39B
39C
Distribution Panel
(For 240/120 V, AT_3 Switches Only)
225 A with (2) 200 A Feeders
300 A with (3) 200 A Feeders
400 A with (4) 200 A Feeders
O
O
O
41
41A
41C
Space Heater with Thermostat
100 Watts
400 Watts
OOO O
O
O
O
O
OO O O O
42 Seismic Zone 4 Certified, CBC, IBC,
UBC, BOCA SS SSSS S S S
45
45A
45B
45C
45D
45E
45F
45G
45H
45I
45J
Load Sequencing Contacts
Load Sequencing Contacts (1)
Load Sequencing Contacts (2)
Load Sequencing Contacts (3)
Load Sequencing Contacts (4)
Load Sequencing Contacts (5)
Load Sequencing Contacts (6)
Load Sequencing Contacts (7)
Load Sequencing Contacts (8)
Load Sequencing Contacts (9)
Load Sequencing Contacts (10)
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O