Specifications

February 2007
16-32
For more information visit: www.eaton.com CA08101001E
Transfer Switches
16
Transfer Switch Equipment
ATC-300 Controller
ATC-300 Controller
ATC-300 Controller
Product Description
AT3 switches are equipped with the
high-performance ATC-300 digital
transfer controller for rock-solid moni-
toring, status reporting and transfer
control operation. Superior design and
robust construction make the AT3 the
industry benchmark for critical and
distributed power systems.
Application Description
The Cutler-Hammer AT3 Automatic
Transfer Switch from Eaton’s electrical
business is designed to provide
unmatched performance, reliability
and versatility for critical standby
power applications.
Features, Benefits and
Functions
Standard Features
Auxiliary relay contacts:
Source 1 Present 2NO & 2NC
Source 2 Present 2NO & 2NC
Switch position indication contacts:
Source 1 Position 1NO & 1NC
Source 2 Position 1NO & 1NC
Source 1 & Source 2 sensing:
Undervoltage/under frequency
Overvoltage/over frequency
3-phase rotation protection
3-phase voltage unbalance/loss
Pre-transfer signal contacts 1NO/
1NC.
Go to Emergency (Source 2).
Seven field programmable time
delays.
LCD-based display for program-
ming, system diagnostic and Help
message display.
Mimic diagram with source avail-
able and connected LED indication.
Time-stamped history log.
System test pushbutton.
Programmable plant exerciser —
OFF, daily, 7, 14, 28-day interval
selectable run time 0 – 600 minutes
no load/load with fail-safe.
Safe manual operation under full
load with permanently affixed
operating handle.
Optional Features
Suitable for Use as Service Equip-
ment in the standard enclosure size.
Available TVSS surge suppression
for power/controller, engine start
circuit, phone and cable
connections.
Integrated distribution panels.
Field-selectable multi-tap trans-
former panel permits operation on a
wide range of system voltages.
Integral overcurrent protection.
Space heater with thermostat.
Ammeter — load side.
Stainless steel cover for controller.
Table 16-37. Programming Selections
Product Specifications
Table 16-38. ATC-300 Controller Specifications
Parameters Set Points
TDNE
TDEN
TDEC
0 to 1800 Seconds
0 to 1800 Seconds
0 to 1800 Seconds
TDES
TDN
TDEF
0 to 120 Seconds
0 to 120 Seconds
0 to 6 Seconds
In Phase Enabled or Disabled
In Phase
Frequency Difference
0.0 to 3.0 Hz
Sync Time 1 to 60 Minutes
Pre-Transfer
Signal Service
0 to 120 Seconds
Plant Exerciser Disabled, 7, 14 or
28 Day Interval,
0 – 600 Minutes,
Load or No Load
Sensing 3-phase or 1-phase
System Selection Utility — Utility or
Utility — Generator
PT Ratio 2:1 to 500:1
Commit to Transfer
in TDNE
0 or 1
Re-Transfer Mode Automatic or Manual
Engine Test Mode Disabled, Load or
No Load
Description Specification
Input Control Voltage 65 to 145 Vac 50/60 Hz
Voltage Measurements of Source 1 V
AB
Source 1 V
BC
Source 1 V
CA
Source 2 V
AB
Source 2 V
BC
Source 2 V
CA
Voltage Measurement Range 0 to 790 Vac rms (50/60 Hz)
Voltage Measurement Accuracy ±2% of nominal input voltage
Frequency Measurement for Source 1 and Source 2
Frequency Measurement Range 40 Hz to 70 Hz
Frequency Measurement Accuracy ±0.1 Hz
Undervoltage Dropout Range 50% to 90% of nominal voltage
Undervoltage Pickup Range (Dropout +2%) to 99% of the Nominal System Voltage
Overvoltage Dropout Range 105% to 120% of nominal voltage
Overfrequency Pickup Range 101% to (Dropout -1 Hz) of the Nominal System Frequency
Underfrequency Dropout Range 90 to 97% of the Nominal System Frequency
Underfrequency Pickup Range (Dropout +1 Hz) to 99% of the Nominal System Frequency
Overfrequency Dropout Range 103 to 110% of the Nominal System Frequency
Overfrequency Pickup Range 101% to (Dropout -1 Hz) of the Nominal System Frequency
Operating Temperature Range -20 to +70°C (-4 to +158°F)
Storage Temperature Range -30 to +85°C (-22 to +185°F)
Operating Humidity 0 to 95% Relative Humidity (Non-condensing)
Operating Environment Resistant to Ammonia, Methane, Nitrogen, Hydrogen and
Hydrocarbons
Generator Start Relay 5 A, 1/6 hp @ 250 Vac / 5 A @ 30 Vdc with a 150 W Maximum Load
K1, K2, Pretransfer, Alarm Relays 10 A, 1 – 3 hp @ 250 Vac / 10 A @ 30 Vdc
Applicable Testing UL Recognized Component
Meets Intent of UL 991, 1008
Meets IEC 1000-4-2, 1000-4-3, 1000-4-4, 1000-4-5, 1000-4-6, 1000-4-11
Meets CISPR 11, Class A
Complies with FCC Part 15, Class A
Enclosure Compatibility NEMA 1, NEMA 3R, and NEMA 12
UV Resistant ATC-300 Faceplate