Datasheet

Federstab
Schaltwege-
diagramm für
Rollenhebel
Rollenhebel
DIN EN 50 047
Schaltwege-
diagramm für
Schwenkhebel,
Verstellrollen-
hebel und
Stangenhebel
Schwenkhebel
DIN EN 50 047
Verstellrollen-
hebel
Stangenhebel
NC
11-12
21-22
NC
Zw = 7.1 mm
4.7
0 4.7 9.6
LS-02/L
13-14
21-22
NO
NC
Zw = 7.1 mm
4.7
0 6.5 9.6
LS-11/L
13-14
21-22
NO
NC
Zw = 48˚
32˚
0˚ 46˚ 65˚
LS-11/RL LS-11/RLA
NC
15-16
27-28
NO
Zw = 7.7 mm
3.3
0 4.7 9.6
LS-11D/L
LS-11S/S*
13-14
13-14
21-22
21-22
Zw = 7.1 mm
2.6
0
4.7
9.6
LS-11S/L*
13-14
13-14
21-22
21-22
Zw = 48˚
17˚
0˚
32˚
65˚
LS-11S/RL* LS-11S/RLA* LS-11S/RR*
NC
11-12
21-22
NC
Zw = 7.1 mm
4.7
0 4.7 9.6
LSM-02/L
13-14
21-22
NO
NC
Zw = 7.1 mm
4.7
0 6.5 9.6
LSM-11/L
13-14
21-22
NO
NC
Zw = 48˚
32˚
0˚ 46˚ 65˚
LSM-11/RL LSM-11/RLA
NC
15-16
27-28
NO
Zw = 7.7 mm
3.3
0 4.7 9.6
LSM-11D/L
LSM-11S/S*
13-14
13-14
21-22
21-22
Zw = 7.1 mm
2.6
0
4.7
9.6
LSM-11S/L*
13-14
13-14
21-22
21-22
Zw = 48˚
17˚
0˚
32˚
65˚
LSM-11S/RL*
LSM-11S/RLA*
LSM-11S/RR*
Elektronischer Positionsschalter LSE-Titan
®
den Schaltpunkt variabel einstellen
Der elektronische Positionsschalter LSE verfügt über einen
variabel einstellbaren Schaltpunkt. Zwei schnelle und
prellfreie PNP-Schaltausgänge erlauben hohe Schalt-
frequenzen. Sie sind überlast- sowie bedingt kurzschluss-
fest und mit einem sprunghaften Schaltverhalten aus-
gestattet. Dies garantiert einen definierten und repro-
duzierbaren Schaltpunkt. Der Schaltpunkt selbst liegt
im Bereich von 0,5 mm bis 5,5 mm (Auslieferungs-
zustand = 3 mm).
Das Einstellen auf den „neuen“ Schaltpunkt wird wie
folgt vorgenommen:
Der Stößel muß von der „alten“ in die „neue“ Schalt-
position bewegt werden. Nun ist für die Dauer von 1 sec.
die Set-Taste zu drücken. Die LED blinkt jetzt mit hoher
Taktfrequenz und der neue Schaltpunkt ist remanent
eingestellt.