Technical data
June 2008
40-60
For more information visit: www.eaton.com CA08102001E
Adjustable Frequency Drives
40
SVX9000
Open Drives
Options
Control Panel Options
Table 40-86. Control Panel Factory Options
Table 40-87. Miscellaneous Options
Consult factory.
Brake Chopper Options
The Brake Chopper Circuit option is used for applications that require dynamic
braking. Dynamic Braking resistors are not included with drive purchase. Consult
the factory for dynamic braking resistors which are supplied separately. Resistors
are not UL Listed.
Table 40-88. Brake Chopper Circuit Adder —
NEMA Type 1, NEMA Type 12, Chassis
Note: Delivery code is FP.
Description Factory Installed Field Installed
NEMA Type 1
Option
Code
Adder
U.S. $
Catalog
Number
Price
U.S. $
Local/Remote Keypad SVX9000 Control Panel — This option is standard on all drives and consists
of an RS-232 connection, backlit alphanumeric LCD display with nine indicators for the RUN status
and two indicators for the control source. The nine pushbuttons on the panel are used for panel
programming and monitoring of all SVX9000 parameters. The panel is detachable and isolated
from the input line potential. Include LOC/REM key to choose control location.
A KEYPAD-LOC/REM
Keypad Remote Mounting Kit — This option is used to remote mount the SVX9000 keypad. The
footprint is compatible to the SV9000 remote mount kit. Includes 10 ft. cable, keypad holder and
mounting hardware.
— OPTRMT-KIT-9000X
Description Catalog
Number
Price
U.S. $
9000XDrive — A PC-based tool for controlling and monitoring of the SVX9000. Features include: loading parameters that
can be saved to a file or printed, setting references, starting and stopping the motor, monitoring signals in graphical or text
form, and real-time display. To avoid damage to the drive or computer, SVDrivecable must be used.
9000XDRIVE
SVDrivecable — 6 ft. (1.8m) RS-232 cable (22 gauge) with a 7-pin connector on each end. Should be used in conjunction
with the 9000X Drive option to avoid damage to the SVX9000 or computer. The same cable can be used for downloading
specialized applications to the drive.
SVDRIVECABLE
External Dynamic Braking Resistors — Used with the Dynamic Braking Chopper Circuit to absorb motor regenerative energy
for stopping the load and to dissipate the energy flowing back into the drive. Resistors are separated into Standard Duty and
Heavy-Duty. Standard Duty is defined as 20% duty or less with 100% braking torque, while Heavy-Duty is defined as 50%
duty or less with 150% braking torque. Consult factory.
hp
(I
H
)
Adder U.S. $
208 –
240V
380 –
500V
525 –
690V
2
3
5vt
5ct
7-1/2vt
7-1/2ct
10
15
20
25
30
40
50
60
75
100
125
150
hp
(I
H
)
Adder U.S. $
208 –
240V
380 –
500V
525 –
690V
200vt
200ct
250
300
350
400
450
500
550
600vt
600ct
700vt
700ct
800
900
1000
1200
1350
1500
1600
2000
Table 40-89. Conformal (Varnished) Coating
Adder — 208 – 240V, 380 – 500V, 525 – 690V
(See Catalog Number Description to order.)
Table 40-90. Conformal Coated Board Kits
See Option Catalog Numbers on Page 40-58.
Construct Catalog Numbers for factory
installed per Table 40-72 on Page 40-53.
Replace “__” with the correct Catalog
Number from Page 40-58. Example:
OPTC2V.
Frame Delivery
Code
Adder
U.S. $
FR4
FR5
FR6
FP
FP
FP
FR7
FR8
FR9
FP
FP
FP
FR10
FR11
FR12
FP
FP
FP
FR13
FR14
FP
FP
Field Installed Factory Installed
Catalog
Number
Price
U.S. $
Option
Designator
Adder
U.S. $
OPT_V
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . SS-2