Technical data
June 2008
CA08102001E For more information visit: www.eaton.com
40-31
Adjustable Frequency Drives
40
SLX9000
Open Drives
SLX9000 Series Option Board Kits
The SLX9000 Series drives can accommodate a wide selection
of expander and adapter option boards to customize the
drive for your application needs. The drive’s control unit
is designed to accept a total of two option boards (see
Figure 40-11).
The SLX9000 Drive accommodates the standard I/O and an
integrated RS-485 (Modbus) connector.
Figure 40-11. SLX9000 Series Option Boards
Table 40-39. Option Board Kits
Option card must be installed in one of the slots listed for that card. Slot indicated in Bold is the preferred location.
AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
Johnson Controls Metasys™ N2 Network Communications
The OPTC2 fieldbus board provides communication
between the 9000X Drive and a Johnson Controls
Metasys™ N2 network. With this connection, the drive
can be controlled, monitored and programmed from the
Metasys system. The N2 fieldbus is available as a factory
installed option and as a field installable kit.
Modbus/TCP Network Communications
The Modbus/TCP Network Card OPTCI is used for connect-
ing the 9000X Drive to Ethernet networks utilizing Modbus
protocol. It includes an RJ-45 pluggable connector. This
interface provides a selection of standard and custom
register values to communicate drive parameters. The board
supports 10 Mbps and 100 Mbps communication speeds.
The IP address of the board is configurable over Ethernet
using a supplied software tool.
BACnet Network Communications
The BACnet Network Card OPTCJ is used for connecting
the 9000X Drive to BACnet networks. It includes a 5.08 mm
pluggable connector. Data transfer is Master-Slave/Token
Passing (MS/TP) RS-485. This interface uses a collection of
30 Binary Value Objects (BVOs) and 35 Analog Value Objects
(AVOs) to communicate drive parameters. The card supports
9.6, 19.2 and 38.4 Kbaud communication speeds and
supports network addresses 1 – 127.
Modbus RTU Network Communications
The Modbus Network Card OPTC2 is used for connecting the
9000X Drive as a slave on a Modbus network. The interface
is connected by a 9-pin DSUB connector (female) and the
baud rate ranges from 300 to 19200 baud. Other communi-
cation parameters include an address range from 1 to 247;
a parity of None, Odd or Even; and the stop bit is 1.
Profibus Network Communications
The Profibus Network Card OPTC3 is used for connecting the
9000X Drive as a slave on a Profibus-DP network. The inter-
face is connected by a 9-pin DSUB connector (female). The
baud rates range from 9.6K baud to 12M baud, and the
addresses range from 1 to 127.
E
D
Option Kit
Description
Allowed Slot
Locations
Field Installed Factory Installed SLX9000 Programs
Catalog
Number
Price
U.S. $
Option
Designator
Adder
U.S. $
Extended I/O Card Options
3 DI, 1 RO (NO/NC), 1 DO D OPTAA AA X
3 DI, 1 RO (NO), 1 TI D OPTAI AI X
1 RO (NC/NO), 1 RO (NO), 1 Therm D, E OPTB2 B2 X
1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24V DC/EXT +24V DC
D, E OPTB4 B4 X
3 RO (NO) D, E OPTB5 B5 X
Communication Cards
Johnson Controls N2 D, E OPTC2 CA X
Modbus TCP D, E OPTCI CI X
BACnet D, E OPTCJ CJ X
Modbus D, E OPTC2 . C2 X
Profibus DP D, E OPTC3 C3 X
LonWorks D, E OPTC4 C4 X
Profibus DP (D9 Connector) D, E OPTC5 C5 X
CanOpen (Slave) D, E OPTC6 C6 X
DeviceNet D, E OPTC7 C7 X
Keypad
SLX9000 Series LCD Keypad (Replacement Keypad) KEYPAD-LCD — X
SLX9000 Series Remote Mount Keypad Unit (Keypad
not included, includes 6.5 ft. cable, keypad holder,
mounting hardware)
OPTDRA-02L — X