Specifications
Output Ratings
■
Horsepower;
❑
90V – 132V, 1/4 – 1/2 hp
❑
200 – 240V: 1/2 – 2 hp
■
Frequency Range: 0.1 – 400 Hz
■
Overload Rating: 150% for 60 seconds
■
Frequency Resolution:
❑
Digital: 0.1 Hz
■
Frequency Accuracy
❑
Digital: ± 0.01% of max. frequency
❑
Analog: ± 0.2% of max. frequency
■
Undervoltage Carryover Limit:
0.3 to 25 seconds
Motor Performance
■
Motor Control:
V/Hz
■
Constant Torque:
Standard
■
Speed Regulation:
0.5% of base speed
Input Power
■
Voltage at 50/60 Hz ± 3 Hz
❑
100V – 120V, -10% +10% / 1-phase
❑
200V – 240V, -10% +5% / 1-phase
❑
200V – 240V, -10% +5% / 3-phase
■
Displacement Power Factor:
Better than 0.95
■
Efficiency: Typically greater than 95%
Design Type
■
Microprocessor: 32-Bit
■
Converter Type: Diode
■
Inverter Type: Insulated Gate Bipolar
Transistor
■
Waveform: PWM Volts/Hertz
Environment
■
Operating Temperature:
❑
-10°C to +40°C
■
Humidity: 20 to 90% non-condensing
■
Maximum Elevation: 1000 meters
(3300 ft.)
Codes and Standards
■
NEMA, IEEE, NEC: Design Standards
■
UL Listed
■
cUL Listed
■
CE Marked
Enclosure
■
Standard: Protected Chassis (IP20)
Protective Features
■
Ground Fault: Standard
■
Overload Protection: Standard
■
Overcurrent: Standard
■
Overvoltage: Standard
■
Undervoltage: Standard
■
Overtemperature: Standard
■
Overload Limit: Standard
Set Up Adjustments, Performance
Features, Operator Control and
External Interface
Keypad
■
Alphanumeric Display:
Standard, 1 x 4 character
■
Digital Indications:
RUN/STOP and FORWARD/REVERSE
■
Diagnostics: Last 3 trips with cause
■
LED Status Indicators: 4
(RUN/STOP and FORWARD/
REVERSE)
■
Operator Functions:
RUN/STOP, Speed control (digital or
potentiometer), RESET, MODE Keys
and ENTER.
I/O Terminal Block
■
Analog Inputs:
❑
1 Input: 0 – 10V DC, 4 – 20 mA
❑
Potentiometer: 1K ohm to 2K ohm
❑
Analog Voltage: Nominal 10V DC
(10K ohm input impedance)
❑
Analog Current: Nominal 4 – 20 mA
(250 ohm)
■
Digital Inputs: 4 Programmable
Inputs
■
Digital Outputs: 1 Form A Relay
contact
Programmable Parameters
■
Out of the Box: Factory settings
loaded for quick start-up.
■
Accel. and Decel.: 2 separately
adjustable Linear or S Curve times:
0.1 – 600 seconds
■
DC Injection Braking
■
External Fault: Terminal input
■
Jog: Terminal input
■
Fault Reset: STOP/RESET or terminal
input
■
I/O: NO/NC Selectable
■
Jump Frequencies: 3 (with adjustable
width)
■
Parameter Security: Programmable
software lock
■
Preset Speeds: 2 preset speeds
■
Reversing: Keypad or terminal
■
Speed Setting: Keypad, terminal
or pot
■
RUN/STOP Control: Keypad or
terminal
■
Stop Modes: Decel, coast or DC
injection
Reliability
■
Pretested Components: Standard
■
Surface Mount Technology:
Standard (PCBs)
■
Computerized Testing: Standard
■
Final Test with Full Load: Standard
■
Eaton’s Cutler-Hammer Engineering
Systems and Service: National net-
work of AF drive specialists
Table 40-2. Watts Loss
Horsepower Catalog
Number
Volts Watts Loss
9 kHz
1/4
1/2
NFXF25A0-1
NFXF50A0-1
115V AC 20W
20W
1/4
1/2
1
2
NFXF25A0-2
NFXF50A0-2
NFX001A0-2
NFX002A0-2
230V AC 20W
20W
38W
75W