Technical data

June 2008
40-226
For more information visit: www.eaton.com CA08102001E
Adjustable Frequency Drives
40
CFX9000
Enclosed Drives
CFX9000 Series Option Board Kits
The 9000X Series drives can accom-
modate a wide selection of expander
and adapter option boards to custom-
ize the drive for your application
needs. The drive’s control unit is
designed to accept a total of five
option boards (see Figure 40-126).
The 9000X Series factory installed
standard board configuration includes
an A9 I/O board and an A2 relay output
board, which are installed in slots A
and B.
Figure 40-126. 9000X Series Option Boards
Table 40-335. Option Board Kits
Option card must be installed in one of the slots listed for that card. Slot indicated in Bold is the preferred location.
AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
OPTC2 is a multi-protocol option card.
Modbus RTU Network Communications
The Modbus Network Card OPTC2 is
used for connecting the 9000X Drive
as a slave on a Modbus network. The
interface is connected by a 9-pin DSUB
connector (female) and the baud rate
ranges from 300 to 19200 baud. Other
communication parameters include an
address range from 1 to 247; a parity
of None, Odd or Even; and the stop
bit is 1.
Profibus Network Communications
The Profibus Network Card OPTC3 is
used for connecting the 9000X Drive
as a slave on a Profibus-DP network.
The interface is connected by a 9-pin
DSUB connector (female). The baud
rates range from 9.6K baud to 12M
baud, and the addresses range from
1 to 127.
LonWorks Network Communications
The LonWorks Network Card OPTC4 is
used for connecting the 9000X Drive
on a LonWorks network. This interface
uses Standard Network Variable Types
(SNVT) as data types. The channel
connection is achieved using a
FTT-10A Free Topology transceiver
via a single twisted transfer cable. The
communication speed with LonWorks
is 78 kBits/s.
A
B
C
D
E
Option Kit
Description
Allowed Slot
Locations
Field Installed Factory Installed SVX Ready Programs
Catalog
Number
Price
U.S.$
Option
Designator
Adder
U.S.$
Basic Local/
Remote
Standard MSS PID Multi-P. PFC
Standard I/O Cards (See Figure 40-126)
2 RO (NC/NO) B OPTA2 XX X XXXX
6 DI, 1 DO, 2 AI, 1AO,
1 +10V DC ref, 2 ext
+24V DC/ EXT +24V DC
A OPTA9 XX X XXXX
Extended I/O Card Options
6 DI, 1 ext
+24V DC/EXT +24V DC
B, C, D, E OPTB1 B1 —— XX
1 RO (NC/NO), 1 RO (NO),
1 Therm
B, C, D, E OPTB2 B2 —— XX
1 AI (mA isolated),
2 AO (mA isolated), 1 ext
+24V DC/EXT +24V DC
B, C, D, E OPTB4 B4 XX X XXXX
3 RO (NO) B, C, D, E OPTB5 B5 —— XX
1 ext +24V DC/EXT +24V
DC, 3 Pt100
B, C, D, E OPTB8 B8 ——
1 RO (NO), 5 DI
42 – 240V AC Input
B,C, D, E OPTB9 B9 —— XX
Communication Cards
Modbus D, E OPTC2 C2 XX X XXXX
Johnson Controls N2 D, E OPTC2 CA ——
Profibus DP D, E OPTC3 C3 XX X XXXX
LonWorks D, E OPTC4 C4 XX X XXXX
Profibus DP
(D9 Connector)
D, E OPTC5 C5 XX X XXXX
CanOpen (Slave) D, E OPTC6 C6 XX X XXXX
DeviceNet D, E OPTC7 C7 XX X XXXX
Modbus
(D9 Type Connector)
D, E OPTC8 C8 XX X XXXX
Modbus TCP D, E OPTCI CI XX X XXXX
BACnet D, E OPTCJ CJ XX X XXXX
Ethernet IP D, E OPTCK CK XX X XXXX
RS-232 with
D9 Connection
D, E OPTD3 D3 XX X XXXX
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . SS-3