Technical data

June 2008
40-140
For more information visit: www.eaton.com CA08102001E
Adjustable Frequency Drives
40
SPX9000
Johnson Controls Metasys™ N2 Network
Communications
The OPTC2 fieldbus board provides
communication between the 9000X
Drive and a Johnson Controls
Metasys™ N2 network. With this con-
nection, the drive can be controlled,
monitored and programmed from the
Metasys system. The N2 fieldbus is
available as a factory installed option
and as a field installable kit.
Modbus/TCP Network Communications
The Modbus/TCP Network Card OPTCI
is used for connecting the 9000X Drive
to Ethernet networks utilizing Modbus
protocol. It includes an RJ-45 plugga-
ble connector. This interface provides
a selection of standard and custom
register values to communicate
drive parameters. The board supports
10 Mbps and 100 Mbps communica-
tion speeds. The IP address of the
board is configurable over Ethernet
using a supplied software tool.
BACnet Network Communications
The BACnet Network Card OPTCJ
is used for connecting the 9000X Drive
to BACnet networks. It includes a
5.08 mm pluggable connector. Data
transfer is Master-Slave/Token
Passing (MS/TP) RS-485. This interface
uses a collection of 30 Binary Value
Objects (BVOs) and 35 Analog Value
Objects (AVOs) to communicate drive
parameters. The card supports 9.6,
19.2 and 38.4 Kbaud communication
speeds and supports network
addresses 1 – 127.
Ethernet/IP Network Communications
The Ethernet/IP Network Card OPTCK
is used for connecting the 9000X Drive
to Ethernet/Industrial Protocol net-
works. It includes an RJ-45 pluggable
connector. The interface uses CIP
objects to communicate drive parame-
ters (CIP is “Common Industrial Proto-
col”, the same protocol used by
DeviceNet). The board supports 10
Mbps and 100 Mbps communication
speeds. The IP address of the board is
configurable by Static, BOOTP and
DHCP methods.
Modbus RTU Network Communications
The Modbus Network Card OPTC2 is
used for connecting the 9000X Drive
as a slave on a Modbus network. The
interface is connected by a 9-pin DSUB
connector (female) and the baud rate
ranges from 300 to 19200 baud. Other
communication parameters include an
address range from 1 to 247; a parity
of None, Odd or Even; and the stop
bit is 1.
Profibus Network Communications
The Profibus Network Card OPTC3 is
used for connecting the 9000X Drive as
a slave on a Profibus-DP network. The
interface is connected by a 9-pin DSUB
connector (female). The baud rates
range from 9.6K baud to 12M baud,
and the addresses range from 1 to 127.
LonWorks Network Communications
The LonWorks Network Card OPTC4 is
used for connecting the 9000X Drive
on a LonWorks network. This interface
uses Standard Network Variable Types
(SNVT) as data types. The channel
connection is achieved using a
FTT-10A Free Topology transceiver
via a single twisted transfer cable. The
communication speed with LonWorks
is 78 kBits/s.
CanOpen (Slave) Communications
The CanOpen (Slave) Network Card
OPTC6 is used for connecting the
9000X Drive to a host system. Accord-
ing to ISO11898 standard cables to be
chosen for CAN bus should have a
nominal impedance of 120Ω, and
specific line delay of nominal 5 nS/m.
120Ω line termination resistors
required for installation.
DeviceNet Network Communications
The DeviceNet Network Card OPTC7
is used for connecting the 9000X Drive
on a DeviceNet Network. It includes a
5.08 mm pluggable connector. Trans-
fer method is via CAN using a 2-wire
twisted shielded cable with 2-wire bus
power cable and drain. The baud rates
used for communication include 125K
baud, 250K baud and 500K baud.
Options
Control Panel Options
Table 40-214. Control Panel Factory Options
Description Factory Installed Field Installed
NEMA Type 1
Option
Code
Adder
U.S. $
Catalog
Number
Price
U.S. $
Local/Remote Keypad SVX9000 Control Panel — This option is standard on all drives and con-
sists of an RS-232 connection, backlit alphanumeric LCD display with nine indicators for the RUN
status and two indicators for the control source. The nine pushbuttons on the panel are used for
panel programming and monitoring of all SPX9000 parameters. The panel is detachable and iso-
lated from the input line potential. Include LOC/REM key to choose control location.
A KEYPAD-LOC/REM
Keypad Remote Mounting Kit — This option is used to remote mount the SPX9000 keypad. The
footprint is compatible to the SV9000 remote mount kit. Includes 10 ft. cable, keypad holder and
mounting hardware.
OPTRMT-KIT-9000X
Keypad Blank — 9000X Series select keypad for use with special and custom applications. KEYPAD-BLANK
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . SS-2