Catalog Number Selection
Table 40-166. SVX9000 Enclosed NEMA Type 12/3R Drive Catalog Numbering System
Consult factory.
Local/Remote keypad is included as the standard Control Panel.
Brake Chopper is a factory installed option only, see drive option tables on Pages 40-118 40-123. Note: External dynamic braking resistors not
included. Consult factory.
Includes local/remote speed reference switch.
Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
See Page 40-115 for descriptions.
See Pages 40-116 and 40-117 for complete descriptions.
Bypass options applicable only in the Pump Panel three-phase design.
S V X 0 1 0 2 4 E P
Enclosed Options

Type
K1
K2
K5
K6
K9
Door-Mounted Speed Potentiometer
Door-Mounted Speed Potentiometer with
HOA Selector Switch
Manual/Auto Reference Switch (22 mm)
Start & Stop Pushbuttons (22 mm)
(2) Factory Installed Auxiliary Contacts
Control
Control
Control
Control
Power
L1
L2
LD
LE
LU
LW
LY
Power On and Fault Pilot Lights
Bypass Pilot Lights for RA Bypass Option
Green Stop Light
Red Run Light
Light (22 mm)
PTT Light (22 mm)
Adder for LED Each
Light
Addl. Bypass
Light
Light
Light
Light
Light
P1
P3
P7
P8
PE
Input Disconnect (HMCP) 100 kAIC
Input Line Fuses (200 kAIC)
Input Power Surge Protection
TVSS Transient Voltage Surge Suppressor
Output Contactor
Input
Input
Input
Input
Output
RA
Manual HOA Bypass Controller
Bypass
S5
S9
SA
SB
SE
SF
Floor Stand 22"
Space Heater w/out CPT
Space Heater w/CPT
Socket Type Control Relay
On-Delay Timer
Off-Delay Timer
Enclosure
Enclosure
Enclosure
Enclosure
Enclosure
Enclosure
Voltage Rating
Three-Phase
1 = 208V
2 = 230V
4 = 480V
Single-Phase
J = 230V
K = 480V
Product Family
SVX = Enclosed Drives
Horsepower Rating
F07 = 3/4 hp
001 = 1 hp
F15 = 1-1/2 hp
002 = 2 hp
003 = 3 hp
005 = 5 hp
007 = 7-1/2 hp
010 = 10 hp
015 = 15 hp
020 = 20 hp
025 = 25 hp
030 = 30 hp
040 = 40 hp
050 = 50 hp
060 = 60 hp
075 = 75 hp
100 = 100 hp
125 = 125 hp
150 = 150 hp
200 = 200 hp
Consult Factory
250 = 250 hp
300 = 300 hp
350 = 350 hp
400 = 400 hp
Enclosure Rating
2 = NEMA Type 12
3 = NEMA Type 3R
Application — Torque/Braking
A = I
L
/No Brake Chopper
B = I
L
/Internal Brake Chopper
D = I
H
/No Brake Chopper
E = I
H
/Internal Brake Chopper
Enclosed Style
P = Pumping Application
Control Options
B1 = 6 DI, 1 ext +24V DC/EXT +24V DC
B2 = 1 RO (NC/NO), 1 RO (NO), 1 Therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24V DC/EXT +24V DC
B5 = 3 RO (NO)
B8 = 1 ext +24V DC/EXT +24V DC, 3 Pt100
B9 = 1 RO (NO), 5 DI 42 – 240V AC Input
Build Alphabetically and Numerically
Communication Options
C2 = Modbus
C3 = Profibus DP
C4 = LonWorks
C5 = Profibus DP (D9 Connector)
C6 = CanOpen (Slave)
C7 = DeviceNet
C8 = Modbus (D9 Type Connector)
CA = Johnson Controls N2
CI = Modbus TCP
CJ = BACnet
CK = Ethernet IP
D3 = RS-232 with D9 Connection