User Manual
Retention
285
08/04 AWB2528-1423GB
Press ESC to exit the input of the retentive ranges.
Up to six differing ranges can be selected.
Example:
MB 01 to MB 04, C 12 to C 16, DB 01 to DB 16, T 26 to T 32
should be retentive.
124 bytes have been assigned to the retentive data range.
76 bytes are still available.
Deleting ranges
Set the ranges to be erased to the values from 00 to 00.
e.g.:
MB 00 -> MB 00. The markers are no longer
retentive.
Deleting retentive actual values of markers and
function blocks
The retentive actual values are cleared if the following is
fulfilled (applies only in STOP mode):
• When the circuit diagram is transferred from
EASY-SOFT(-PRO) (PC) or from the memory card to easy,
the retentive actual values are reset to 0. This also applies
when there is no program on the memory card. In this case
the old circuit diagram is retained in easy.
• When changing the respective retentive range.
• When the circuit diagram is deleted via the DELETE
PROGRAM menu.
CI 00 -> CI 00 Æ
DB 00 -> DB 00
T 00 -> T 00 æ
B:200
h
The display on the lower right B:200 indicates the
number of free bytes.
MB 01 -> MB 04
C 12 -> C 16
CH 00 -> CH 00
CI 00 -> CI 00
DB 01 -> DB 16
T 26 -> T 32
B:076