User Manual
Function blocks
191
08/04 AWB2528-1423GB
Output
The function block output
QV> can be assigned the
following operands:
• Markers MD, MW, MB
• Analog output QA01
Value range for inputs and outputs
Example:
Displaying the parameter set in the PARAMETERS
menu
• + Access enabled
• – Access disabled
Coil
FT01EN to FT32EN, function block enable
Memory requirement of the FT function block
The FT function block requires 56 bytes of memory plus
4 bytes per constant on the function block input.
Value range Resolution/Unit
>I1 Input value of the function
block
–32 768 to +32767
>TG Recovery time T
g
0 to 65535 in 100/ms
>KP Proportional gain K
p
0 to 65535 in -- /%
QV> Output value –32 768 to +32767
Value at input Value processed in
the function block.
>TG Recovery time T
g
250 25 s
>KP Proportional gain K
p
1500 15