User Manual

Wiring with easy800
182
08/04 AWB2528-1423GB
Analog inputs IA01 to IA04
IA01: terminal I7
IA02: terminal I8
IA03: terminal I11
IA04: terminal I12
Analog output QA01
Actual value
QV> of another function block
Output
The function block output QV> can be assigned with the
following operands:
Markers MD, MW, MB
Analog output QA01
Contacts
DB01Q1 to DB32Q1
Contact (make contact) DB..Q1 switches to status 1 if the
trigger signal is set to 1.
Coils
DB01T_ to DB32T_, acceptance of the value at >I1 with a
rising edge.
Memory requirement of the data function block
The data block function block requires 36 bytes of memory
plus 4 bytes per constant at the function block input.
Retention
Data function blocks can be operated with retentive actual
values. The quantity can be selected in the SYSTEM r
RETENTION menu.