User Manual
Wiring with easy800
180
08/04 AWB2528-1423GB
Figure 81: Text output examples
Entering a setpoint in a display
This function is available from device version 04.
The setpoints of function blocks can be incorporated within
a text. This is useful if the PARAMETERS menu is not
available for making entries.
The example shows the following: The setpoint of timing
relay T01 is to be changed from 12 s to 15 s.
• Line 1: Actual value of timing relay T 01
• Line 2: Setpoint of timing relay T 01, editable
X Press the ALT button to move the cursor to the first
editable value.
In this operating mode, you can use the cursor buttons
ÍÚ
to move between editable constants.
X Press the OK button to move the cursor to the least
significant value of the constant to be modified.
Counter with actual value Analog values scaled as
temperature values
D1 as error message on fuse
failure
QUANTITY
QTY: 0042
!COUNTING!
TEMPERATURE
OUT -010 DEG
IN +018 DEG
HEATING
FUSE FAULT
HOUSE 1
FAILED!
h
The appropriate text function block must be available in
order to modify a setpoint. The setpoint must be a
constant.
h
The text remains static on the display while the values are
entered. The actual values are updated.
ACT T01: 000:000
SETP : 012:000
ACT C16: 04711
SET : 10000
ACT T01: 000:000
SETP : 012:000
ACT C16: 04711
SET : 10000
ACT T01: 000:000
SETP :
012:0000
ACT C16: 04711