User Manual

Wiring with easy800
158
08/04 AWB2528-1423GB
7: reset coil C..RE
8: contact (make contact) C..OF upper setpoint value reached,
exceeded
9: contact (make contact) C..FB lower setpoint value reached,
undershot
10: actual value equal to zero
11: out of value range
•Range A:
The counter has the value zero.
The contacts C..ZE (actual value equal to zero) and C..FB
(lower setpoint value undershot) are active.
The counter receives counter values and increases the actual
value.
C..ZE drops out as well as C..FB and also when the lower
setpoint value is reached.
•Range B:
The counter counts upwards and reaches the upper setpoint
value. The contact “upper setpoint value reached” C..OF
becomes active.
•Range C:
The coil C..SE is briefly actuated and the actual value is set to
the preset actual value. The contacts go to the respective
position.
•Range D:
The counting direction coil C..D_ is actuated. If counting
impulses are present, downward count is initiated.
If the lower setpoint value is undershot, the contact C..FB
becomes active.
Range E:
The reset coil C..RE is activated. The actual value is set to zero.
The contact C..ZE is active.
•Range F:
The actual value goes outside the value range of the counter.
The contacts become active according to the direction of the
values (positive or negative).