User Manual

Function blocks
155
08/04 AWB2528-1423GB
Inputs
The function block inputs
>SH, >SL and >SV can have the
following operands:
•Constants
Markers MD, MW, MB
Analog inputs IA01 to IA04
IA01: terminal I7
IA02: terminal I8
IA03: terminal I11
IA04: terminal I12
Analog output QA01
Actual value
QV> of another function block
Actual value
QV>
The actual value
QV> can be assigned the following
operands:
Markers MD, MW, MB
Analog output QA01
Displaying the parameter set in the PARAMETERS
menu
+ Access enabled
– Access disabled
Contacts
C 01OF to C 32OF: Actual value f upper setpoint
C 01FB to C 32FB: Actual value F Lower setpoint value
C 01ZE to C 32ZE: Actual value = zero
C 01CY to C 32CY: Value range exceeded
Coils
C 01C_ to C 32C_: counter coils, count with rising edge
C 01D_ to C 32D_: count direction definition,
status 0 = count upwards, status 1 = count downwards
C 01RE to C 32RE: Reset actual value to zero
C 01SE to C 32SE: accept defined actual value with rising
edge.