User Manual
Function blocks
141
08/04 AWB2528-1423GB
Contacts
BT01E1 to BT32E1: the number of marker bytes exceeds the 
source or destination range.
BT01E2 to BT32E2: source and destination range overlap. 
Only valid for CPY mode, copy marker ranges.
BT01E3 to BT32E3: the specified offset is invalid.
Coils
BT01T_ to BT32T_: trigger coil of the transfer data block 
function block.
Memory requirement of the transfer data block 
function block
The transfer data block function block requires 48 bytes of 
memory plus 4 bytes per constant at the function block 
inputs.
Function of the transfer data block function block
The transfer data block comparator function block has two 
operating modes.
Initalising INI marker ranges
There is one source range and one destination range. The 
source range is specified at 
>I1. The length of the source 
range is one byte. The destination range is specified at 
>I2. 
The length of the destination range is specified by the 
number of bytes at the 
>NO input.
The content of the source range is transferred to the marker 
bytes in the destination range.
The function block executes the transfer if there is a rising 
edge from 0 to 1 at the BT..T_ (Trigger) coil.
The error outputs E1, E2 and E3 are evaluated regardless of 
the status of the trigger.
h