Function blocks
129
08/04 AWB2528-1423GB
Inputs
The function block inputs
>I1 and >I2 can have the
following operands:
•Constants
Markers MD, MW, MB
Analog inputs IA01 to IA04
IA01: terminal I7
IA02: terminal I8
IA03: terminal I11
IA04: terminal I12
Analog output QA01
Actual value
QV> of another function block
Actual value
QV>
The actual value
QV> can be assigned the following
operands:
Markers MD, MW, MB
Analog output QA01
An arithmetic function block is not wired in the circuit
diagram.
Parameter display and parameter set for arithmetic function
blocks:
Only constants can be modified in the parameter display of
a function block.
AR32 ADD +
>I1
>I2
QV>
AR32 Arithmetic function block number 32
ADD Addition mode
+ Appears in the parameter display
>I1 First value
>I2 Second value
QV> Result of the addition