User Manual
Wiring with easy800
110
08/04 AWB2528-1423GB
The first contact or coil from the call position to the end of
the circuit diagram is sought. If no contact or coil is found,
the easy800 circuit diagram editor will continue the search
from the start of the circuit diagram. If a contact or coil is
found, the easy800 editor automatically jumps to the
respective field in the circuit diagram.
“Go to” a circuit connection
The easy800 circuit diagram editor provides a Go To function
in order to enable fast access to a circuit connection.
X Press ESC and use the ÍÚ cursor buttons to select the GO
TO menu.
X Press OK.
X Select the required rung (L... …) with the ÍÚ cursor
buttons.
The first contact on the circuit connection is always
indicated.
X Press OK.
The cursor remains stationary at the required circuit
connection contact L 1.
Deleting the rung
easy800 only removes empty circuit connections (without
contacts or coils).
X Delete all the contacts and coils from the circuit
connection.
X Position the cursor on the first contact field of the empty
circuit connection.
X Press DEL.
I 01----I 02---
Q 01----HY01Q1k
L: 1 C:1 B:7140
I 01----I 02---
Q 01----HY01Q1k
L: 1 C:1 B:7140
I 01----I 02---
Q 01----HY01Q1k
L: 1 C:1 B:7140