Installation Manual
Table Of Contents
Instructions Publication P20773
Effective May 2011
E57 Wiring Diagram
DC and AC Version
Eaton Corporation
Electrical Sector
1111 Superior Avenue
Cleveland, OH 44114
United States
877-ETN-CARE (877-386-2273)
Eaton.com
© 2011 Eaton Corporation
All Rights Reserved
Publication No. P20773 / 006
May 2011
Eaton is a registered trademark of Eaton
Corporation.
All other trademarks are property of their
respective owners.
2-WIRE, CABLE, N.O. or N.C.
2-WIRE, CABLE, N.O. or N.C.
2-WIRE, MICRO-CONNECTOR, N.O. or N.C.
1
2-WIRE, MINI-CONNECTOR
1
3-WIRE, AC/DC, CABLE
3-WIRE, AC/DC, MICRO-CONNECTOR
3-WIRE, AC/DC, MINI-CONNECTOR
FOR HIGH VIBRATION INSTALLATION
USE A SUITABLE THREAD LOCKING COMPOUND OR LOCKWASHER.
RD
BK
L1 or
(-)
L2 or
+V
WH
Load
L2 or +V
L1
or (-)
Load
L2 or +V
L1 or (-)
Load
BU
BN
L2
L1
Load
L2
L1
*
* Internally connected to housing
(use of this wire is optional)
Load
L1
L2
Load
*
* Internally connected to housing
(use of this wire is optional)
BU
BN
L2
L1
Yellow/Green
* Internally connected to housing
(use of this wire is optional)
*
Load
12mm Devices: Connector cordset grounding conductor.
18mm & 30mm Devices: Double insulated, cordset grounding conductor is not connected to
proximity switch enclosure. Equipment grounding conductor is not required.
Maximum Torque Limits for Metal & Plastic Tubes
METAL TUBES PLASTIC TUBES
Sensor Dia. mm Torque Lb. Ft. (Nm) Torque Lb. Ft. (Nm)
8 4 (5.5) (-)
12 4 (5.5) 2 (2.7)
18 15 (20) 4 (5.4)
30 30 (41) 6 (8.1)
Note: Do not exceed these torque limits when thightening the hex nuts.
Metal nuts are provided for equipment grounding means.
AC Version