Technical Bulletin

EtherNet/IP On-Board Communications
60 PowerXL DG1 Series VFD MN040010EN—May 2014 www.eaton.com
Note: Configurable–Faults that are specified as
“Configurable” have “Fault configuration parameter”
associated with them. This configuration parameter
can be configured as using keypad (menu P9.
Protections) or using PowerXL EIP vendor specific
object.
1. No action
2. Warning
3. Fault
4. Fault, Coast
17 IP conflict Configurable Warning MCU A006h
18 Power board EEPROM Fault
Fault MCU A007h
19 FRAM Fault
Fault MCU A008h
20 Serial Flash Fault
Warning MCU A009h
21 MCU WatchDog Fault
Fault MCU 6010h
22 Start-up Prevent
Fault MCU A00Ah
23 Thermistor Fault
Configurable Fault MCU 7300h
24 Fan Cooling
Fault DSP A00Bh
25 Compatibility Fault
Fault MCU 5200h
26 Device Change
Warning MCU A00Ch
27 Device Added
Warning MCU A00Dh
28 Device Removed
Fault MCU A00Eh
29 Device Unknown
Fault MCU A00Fh
30 IGBT Temperature
Fault DSP 66d
31 Encoder Fault
Fault MCU 7305h
32 AIN<4mA(4to20mA)
Configurable No Action MCU A011h
33 External Fault
Configurable Fault MCU 9000h
34 Keypad Communication Fault
Fault MCU A012h
35 FieldBus communication Fault
Configurable No Action MCU 8100h
36 OPT Card Fault
Configurable Fault MCU A013h
37 BypassOverLoad
Fault MCU A014h
38 Real time clock fault
Configurable Warning MCU A015h
39 PT100 Fault
Configurable Fault MCU A016h
40 Motor ID fault
Fault DSP A017h
41 Current Measure Fault
Fault DSP 2100h
42 Possible power wiring error detected
Fault DSP 5400h
43 Control Board OverTemp
Fault DSP 4300h
44 Internal-ctrl Supply
Fault MCU 5112h
45 Too Many Speed Search Restarts
Fault DSP A018h
46 Current Unbalance
Fault DSP 26d
47 Replace Battery
Configurable Warning MCU A019h
48 Replace Fan
Configurable Warning MCU A01Ah
49 Safety Torque Off
Fault DSP A01Bh
50 Current Limit Control
Warning DSP 0x2200
51 Over Voltage Control
Warning DSP 0x3310
Table 81. List of Fault Codes Supported By PowerXL EtherNet/IP, continued
Fault Code Fault Description Fault/Warning Default Realization CIP Fault code