Installation Manual
Chapter 6—Installation Requirements
DG1 Series VFD MN040002EN—March 2014 www.eaton.com 25
Dimensions
Approximate Dimensions in mm
Figure 17. Type 1/12 Open Drives
Note
1
FR6 and 575 Vac available in 2015.
Table 18. Mounting Drive Dimensions
Frame
Size Voltage hp (CT/I
H
)kW
Amperes
(CT/I
H
)
Approximate Dimensions in Inches (mm)
Weight
Lb (kg)D H1 H2 H3 W1W2W3W4Ø
FR1 230 Vac 0.75–3 0.55–2.2 3.5–11 7.89
(200.4)
12.87
(326.9)
12.28
(311.9)
11.50
(292.1)
6.02
(153.0)
4.80
(121.9)
3.94
(100.1)
3.94
(100.1)
0.28
(7.0)
14.33
(6.5)
480 Vac 1–5 0.75–3.7 2.3–7.6
575 Vac
1
2–5 1.5–3.7 3.3–7.5
FR2 230 Vac 5–7.5 3–5.5 12.5–25 9.63
(244.7)
16.50
(419.1)
15.98
(405.9)
14.96
(380.0)
6.61
(167.8)
5.28
(134.1)
3.54
(90.0)
3.54
(90.0)
0.28
(7.0)
23.37
(10.6)
480 Vac 7.5–15 5.5–11 12–23
575 Vac
1
7.5–15 5.5–11 10–18
FR3 230 Vac 10–15 7.5–11 31–48 10.44
(265.1)
21.97
(558.0)
21.46
(545.0)
20.43
(518.9)
8.06
(204.6)
7.24
(183.9)
4.92
(125.0)
4.92
(125.0)
0.35
(9.0)
49.82
(22.6)
480 Vac 20–30 15–22 31–46
575 Vac
1
20–30 15–22 22–34
FR4 230 Vac 20–30 15–22 61–88 11.57
(294.0)
24.80
(629.9)
34.31
(617.5)
23.27
(591.1)
9.36
(237.7)
9.13
(231.9)
8.07
(205.0)
8.07
(205.0)
0.35
(9.0)
77.60
(35.2)
480 Vac 40–60 30–45 61–87
575 Vac
1
40–60 30–45 41–62
FR5 230 Vac 40–60 30–45 114–170 13.41
(340.7)
34.98
(888.5)
29.65
(753.1)
27.83
(706.9)
11.34
(288.0)
11.10
(281.9)
8.66
(220.0)
8.66
(220.0)
0.35
(9.0)
154.32
(70.0)
480 Vac 75–125 55–90 105–170
575 Vac
1
75–125 55–90 80–125
FR6
1
230 Vac 75–100 55–75 211–261
1111111111
480 Vac 150–200 110–150 205–261
575 Vac
1
150–200 110–160 144–208
W3
H2
W4
W1
W2
H1
D
H3