Technical data

April 2008
16-46
For more information visit: www.eaton.com PG03300001E
Accessories & Modification Codes
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Modification Codes
Table 16-144. S — System Voltage, Selector Switches, Suppressor,
Incomplete Sequence Protection, Single-Phase Jumper, Surge
Capacitor, Speed Potentiometer
When using 3-position selector switch with magnetic lighting
contactor, mod C20 must also be used (ECL04, ECL13, ECL15).
Not available for IT. Starters.
Table 16-145. T — Timers, Time Delay Relays, Terminal Blocks,
Terminal Points, Ring Lug Connections
Not available for IT. Starters.
Not available for XT Starters.
Modification Catalog
Number
Suffix
Description
System Voltage
Selection
S1 System Voltage Selection for Internal
Components
/H1 208V 60 Hz
/H2 240V 60 Hz
/H3 277V 60 Hz, 1-Ph
/H4 480V 60 Hz
/H5 600V 60 Hz
/H6 796V 60 Hz
/H7 220V 50 Hz
/H8 380V 50 Hz
/H9 415V 50 Hz
/H10 550V 50 Hz
/H11 660V 50 Hz
/H12 380V 60 Hz
/H13 1500V 60 Hz
S2
System Voltage Selection — Specify on Order
Selector
Switches
S3 HAND/OFF/AUTO
S4 HAND/AUTO
S5 HAND/OFF/AUTO Selector Switch with 1 Red
RUN Pilot Light
S6 RUN/OFF/AUTO
S7 AUTO/OFF/TEST
S8 AUTO/OFF/TEST Selector Switch with 1 Red
RUN Pilot Light
S9 AUTO/OFF/TEST Selector Switch with 1 Red
RUN Pilot Light and 1 Green Pilot Light
S10 OFF/AUTO
S11 START/STOP
S12 OFF/ON
S13
HIGH/LOW
S14
FAST/OFF/SLOW
S15
SLOW/FAST
S16
FORWARD/REVERSE
S17
HIGH/OFF/LOW
S18
HIGH/LOW/OFF/AUTO
S21 HAND/OFF/AUTO Spring Return from Left
S38
INVERTER/OFF/BYPASS (MVX)
S41
OPEN/OFF/CLOSE
S42
FORWARD/OFF/REVERSE
S43
FAST/OFF/SLOW/AUTO
S19
Selector Switch Omitted (Pump Panels Only)
S40 Selector Switch — Order by Description
Suppressor S24
Transient Suppressor Mounted
on Magnet Coil
Surge
Suppression
S20 MOV (IT.)
Sequence
Timer
S26
Sequence Timer (Pump Panels)
Sequence
Protection
S27
Incomplete Sequence Protection
Pump S28 480V BP9000 Pump
Single Phase
S29 Convert Contactor or Starter from Three-
Phase to Single-Phase — Install Jumper
S30 Single-Phase Rev. 120V
S31 Single-Phase Rev. 240V
Surge
Capacitor
S37
Surge Capacitor Wired to Disconnect Line
Side
Speed
Potentiometer
S39
Speed Potentiometer (MVX)
Modification Catalog
Number
Suffix
Description
Timers T1
Pneumatic Timer Installed on Contactor,
Unwired, 30 Sec. Max.
T2
Pneumatic Timer Installed on Contactor,
Unwired, 180 Sec. Max.
T3 Pneumatic Timer Mounted in Enclosure,
Unwired, 180 Sec. Max.
T4 Solid-State ON Delay Timer (1 – 30 sec)
T5 Solid-State ON Delay Timer (30 – 300 sec)
T25 Timer — Order by Description
Time Delay
Relays
T6 Time Delay Relay, 3 Minutes Maximum,
Unwired, ON DELAY
T7 Time Delay Relay, 3 Minutes Maximum,
Unwired, OFF DELAY
T8 Time Delay Low Voltage Release Relay
Terminal
Blocks
T9 With 1 Single Circuit Terminal Block,
Unwired
T10 With 2 Single Circuit Terminal Block,
Unwired
T24
Power Terminal Block for DeviceNet
Overload
Terminal
Points
T11 With 6 Terminal Points, Unwired
T12 With 12 Terminal Points, Unwired
T13 With 18 Terminal Points, Unwired
T14 Terminal Point per Customer Specification,
Unwired (Price Each)
T15 Terminal Point per Customer Specification,
Wired (Price Each)
T21
3 Terminals Mounted Between Contactor
and Overload for Power Factor Capacitors —
Sizes 0 – 2
T22
3 Terminals Mounted Between Contactor
and Overload for Power Factor Capacitors —
Sizes 3 – 4
T23
Quick-Connect Terminals Added to DP
Contactor/Starter
Ring Lug
Connections
T16
Ring Lug Connections on Power Wires
T17
Ring Lug Connections on Control Wires
IT./EM T30 Reset Only
T31 STOP with Reset
T32 START/STOP with Reset
T33A HAND/OFF/AUTO with Reset 120V AC
T33D HAND/OFF/AUTO with Reset 24V DC
T34 ON/OFF
T40 Reset Only (DeviceNet)
T41 STOP with Reset (DeviceNet)
T42 START/STOP with Reset (DeviceNet)
T43A HAND/OFF/AUTO with Reset 120V AC
(DeviceNet)
T43D HAND/OFF/AUTO with Reset 24V DC
(DeviceNet)
T44 ON/OFF
T50 Reset Only
T51 STOP with Reset
T52 FORWARD/REVERSE/STOP with Reset
T53A FORWARD/REVERSE/STOP with Reset
120V AC
T53D FORWARD/REVERSE/STOP with Reset
24V DC
T54 ON/OFF