Technical data
April 2008
PG03300001E For more information visit: www.eaton.com
16-45
Accessories & Modification Codes
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Modification Codes
Table 16-142. Q — IQ Products, DN50
Not available for IT. Starters.
Table 16-143. R — Ramp, Relays, Solid-State Electronic Overload
Relays, Resets, Overload Relay Modifications, Reversing,
DeviceNet Interface
Not available for IT. Starters.
Not available for XT Starters.
Table 16-143. R — Ramp, Relays, Solid-State Electronic Overload
Relays, Resets, Overload Relay Modifications, Reversing,
DeviceNet Interface (Continued)
Not available for IT. or XT Starters.
Features:
• Self-Powered
• Phase Loss Protection
• Current Adjustment Knob
• ± 1% Repeat Accuracy
• 1NO and 1NC Isolated Contacts
Complete Modification Code includes overload range. Example R61/C.
Modification Catalog
Number
Suffix
Description
IQ Products Q1 IQ 500
Q3 IQ 1000
Q5 IQ 4000
Q8 With Wponi (Advantage)
Q9 With WCTLponi (Advantage)
IQ Data
Metering
Module
Q12
IQ Data Metering Module
Q14 IQ 220 with Cable
DN50 Q13
DeviceNet Input/Output Module
Modification Catalog
Number
Suffix
Description
Ramp R1 Extended Ramp of IT.
Relay
R2 Overvoltage Relay
Fixed Heater
Overload
Relay
R8 C316FNA3C .25 – .40A
R9 C316FNA3D .40 – .63A
R10 C316FNA3E .63 – 1.00A
R11 C316FNA3F 1.00 – 1.40A
R12 C316FNA3G 1.30 – 1.80A
R13 C316FNA3H 1.70 – 2.40A
R14 C316FNA3J 2.20 – 3.10A
R15 C316FNA3K 2.80 – 4.00A
R16 C316FNA3L 3.50 – 5.00A
R17 C316FNA3M 4.50 – 6.50A
R18 C316FNA3N 6.00 – 8.50A
R19 C316FNA3P 7.50 – 11.00A
R20 C316FNA3Q 10.00 – 14.00A
R21 C316FNA3R 13.00 – 19.00A
R22 C316FNA3S 18.00 – 24.00A
R23 C316FNA3T 24.00 – 32.00A
R24 C316KNA3A 18.00 – 25.00A
R25 C316KNA3B 22.00 – 32.00A
R26 C316KNA3C 29.00 – 42.00A
R27 C316KNA3D 36.00 – 52.00A
R28 C316KNA3E 45.00 – 63.00A
R29 C316KNA3F 60.00 – 80.00A
R30 C316PNA3A 65.00 – 90.00A
R31 C316PNA3B 80.00 – 100.00A
R32 C316PNA3C 100.00 – 135.00A
R33 C316PNA3D 110.00 – 150.00A
R34 C316PNA3E 130.00 – 175.00A
R35 C316PNA3F 150.00 – 200.00A
R36 C316SNA3A 130.00 – 185.00A
R37 C316SNA3B 165.00 – 235.00A
R38 C316SNA3C 220.00 – 310.00A
R39 C316SNA3D 285.00 – 400.00A
R40 C316UNA3A 355.00 – 500.00A
R41 C316UNA3B 465.00 – 650.00A
R42 C316UNA3C 610.00 – 850.00A
Modification Catalog
Number
Suffix
Description
Fixed Heater
Overload
Relay,
continued
R43 Fixed Heater Overload Relay — Order by
Description
R55
C316FNA3F
w/Current Transformer
60.00 – 84.00 FLA
R56
C316FNA3G
w/Current Transformer
78.00 – 108.00 FLA
R57
C316FNA3H
w/Current Transformer
102.00 – 144.00 FLA
R58
C316FNA3J
w/Current Transformer
132.00 – 186.00 FLA
R59
C316FNA3K
w/Current Transformer
168.00 – 240.00 FLA
R60
C316FNA3L
w/Current Transformer
210.00 – 310.00 FLA
Solid-State
Electronic
Overload
Relay
IEC
Frame
NEMA
Size
Full Load
Current
Adjustment
Range (A)
3-Phase Automatic/
Manual Reset
Class
5/10/20/30
Catalog Number Suffix
➟
R61_
B & C 00 0.1 – 0.5
0.4 – 2.0
1.0 – 5.0
1.6 – 8.0
A
B
C
D
C & D 0 & 1 0.1 – 0.5
0.4 – 2.0
1.0 – 5.0
1.6 – 8.0
6.4 – 32
A
B
C
D
E
D 2 9 – 45 F
3 15 – 75 G
F & G 22 – 110 H
G 4 30 – 150 J
N/A 5 96 – 300 C
N/A 6 192 – 600 C
Resets
R5 Change External Reset to Internal Reset —
Hole Covered with Plug
R6 Internal Reset — No Hole Plug
R44 Manual Reset Only on Overload Relay
R45 Auto Reset Only on Overload Relay
R47 Internal Trip Indicator — No External Reset
R48 External Reset with External Trip Indicator
R49 External Reset with Bell Alarm
R71 N3R Reset Boot Added (Type 1/12 Only)
Reversing
R54 Reversing Contactor/Starter
Overload
Relay Mods
R53 Anti Plug-In
R61 C395 DNA DeviceNet Module
R62 C395 Bell Alarm
R63 C395 Load Module
R64 C395 Program Key
DeviceNet
Interface
R69 DeviceNet Interface
R65 Standard Reset for DeviceNet
R66 Lighted Reset for DeviceNet
R67 Trip Indicator for DeviceNet
R68 DeviceNet Communication Interface (MVX)