Modification Codes
Table 16-136. G — Ground Fault Relay, Grounding
Table 16-137. H — Heater (Space), Heater Packs Installed
Table 16-138. K — MVX Keypad
See Tab 7 for more MVX Modifcations.
Table 16-139. L — Labels, Line and Load Reactors,
Lighting Contactors
If the power source exceeds 500 kVA, 3% line unbalance, or if transient
voltages from power factor capacitor switching events are present, an
input line reactor must be used. The input line reactor will also reduce
line current harmonics.
The output line DV/DT filter is required when the distance from the
drive to the motor exceeds 33 feet (10m). The total cable run should
not exceed 165 feet (50m).
Table 16-140. N — Nameplates
Modification Catalog
Number
Suffix
Description
Ground Fault
Relay
G1 Ground Fault Relay (Wired)
G3 Ground Fault Relay (Unwired)
Grounding G5 Special Grounding — Order by Description
G6 Ground Fault Protection Omitted
(Advantage)
G7 Ground Fault Protection and Monitoring
Panel
Modification Catalog
Number
Suffix
Description
Space
Heater
H1 Space Heater and Thermostat
H2 Space Heater and NC Interlock
Install Heater
Packs
(Freedom
Series)
H5 Class 20 Class 10
/D1 H2001B-3
/D2 H2002B-3
/D3 H2003B-3
/D4 H2004B-3
/D5 H2005B-3
/D25 H2101B-3
/D26 H2102B-3
/D27 H2103B-3
/D28 H2104B-3
/D29 H2105B-3
/D6 H2006B-3
/D7 H2007B-3
/D8 H2008B-3
/D9 H2009B-3
/D10 H2010B-3
/D30 H2106B-3
/D31 H2107B-3
/D32 H2108B-3
/D33 H2109B-3
/D34 H2110B-3
/D11 H2011B-3
/D12 H2012B-3
/D13 H2013B-3
/D14 H2014B-3
/D15 H2015B-3
/D35 H2111B-3
/D36 H2112B-3
/D37 H2113B-3
/D38 H2114B-3
/D39 H2115-3
/D16 H2016B-3
/D17 H2017B-3
/D18 H2018-3
/D19 H2019-3
/D20 H2020-3
/D40 H2116-3
/D41 H2117-3
/D21 H2021-3
/D22 H2022-3
/D23 H2023-3
/D24 H2024-3
Modification Catalog
Number
Suffix
Description
Keypad
(MVX)
K1 Door-Mounted AFD Keypad (Type 1 and 12)
K2 Door-Mounted AFD Keypad (Type 3R)
K3 AFD Copy Keypad (mounted on drive)
K4 Door-Mounted AFD Copy Keypad
(Type 1 and 12)
K5 Door-Mounted AFD Copy Keypad (Type 3R)
Modification Catalog
Number
Suffix
Description
Carton Label L10 Customer Marking — Specify
Line
Reactors
(MVX)
L12 3% Input Line Reactor, 3-Phase, Open
Core and Coil
L13 3% Input Line Reactor, 1-Phase, Open
Core and Coil
L14 5% Input Line Reactor, 3-Phase, Open
Core and Coil
L15 5% Input Line Reactor, 1-Phase, Open
Core and Coil
L16 Line Reactor — Order by Description
Load
Reactors
(MVX)
L17 Output Line DV/DT Filter, Open Core and
Coil
L18 Load Reactor — Order by Description
Lighting
Contactors
L21 1 NC Pole
L22 2 NC Pole
L23 3 NC Pole
L24 4 NC Pole
L25 5 NC Pole
L26 6 NC Pole
L27 7 NC Pole
L28 8 NC Pole
L29A 3-Wire 120V AC
L29B 3-Wire 240V AC
L29C 3-Wire 24V AC
L29D 3-Wire 24V DC
L29E 2-Wire 120V AC
L29F 2-Wire 240V AC
L29G 2-Wire 24V AC
Modification Catalog
Number
Suffix
Description
Nameplates N1 Enclosure Nameplates