Datasheet
03/20/2012 HPL-ED2011 V2.0 EN (UX111) 2 / 4
 
Back plate: 
2 x push-through diaphragm up to   11 mm
(not for CI-K2H) 
Notes
Cross-referenceNumber and size of cable entries →#229310
Approbationen
UL approval No
CSA approval No
General
Standards   IEC/EN 60529
DIN 43660
EN 50262
Climatic proofing   Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature  °C - 25 - 70
Ambient temperature with push-through cable entry  °C - 25 … 40
Protection type   Front IP65
Degree of protection with push-through cable entry   IP65
Dissipatable heat loss   
   →Radiated heat dissipation
Material�characteristics
Material   
Base, Cover   Glass-fibre reinforced polycarbonate
Colour   
Base   RAL 9005, black (matt)
Cover   Enclosure cover RAL 7035, light grey (matt)
Material�properties
Electrical   
Creepage resistance to IEC 60112   
Base   CTI 175
Cover   CTI 175
Surface resistance to IEC 60093  Ω x
10
13
1
Dielectric strength to IEC 60243-1  kV/
mm
30
Thermal   
Continuous thermal stability   
Enclosures  °C -40 … 120
Gasket  °C -40 … 80
Mechanical   
IK code to EN 50102   06
max. assembly weights   
per mounting rail  kg 0.7
Chemical resistance   
Base, Cover   
Resistant   Acids < 10 %, mineral oil, petrol, grease, saline solution
Partially resistant   Acids > 10 %, alcohol
Not resistant   Alkalis, benzol