Selection Guide
Eaton Corporation
Electrical Group
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN-CARE (877-386-2273)
Eaton.com
© 2009 Eaton Corporation
All Rights Reserved
Publication No. TD03701001E
April 2009
PowerChain Management is a registered
trademark of Eaton Corporation.
All other trademarks are property of their
respective owners.
Quick Selector TD03701001E
April 2009
Lighting Contactors for
the Construction Market
A202 Magnetically Latched – Overview
• Designed with a permanent magnet that
will maintain the contactor in its
energized state indefi nitely without using
control power
• Ideal for applications where contact closure
is required during power failure
• Easy to install and maintain
• No control power necessary to maintain contact closure
A202 Contactors – Model Selection
Holding Circuit Auxiliary Contact or Pushbutton Station Not Included
Continuous Amperes
(Enclosed) Number of Poles
Open Type
Catalog Number
1, 2
30 2 A202K1B_M
3 A202K1C_M
4 A202K1D_M
5 A202K1E_M
6 A202K1F_M
8 A202K1G_M
10 A202K1H_M
12 A202K1K_M
60 2 A202K2B_M
3 A202K2C_M
4 A202K2D_M
5 A202K2E_M
6 A202K2F_M
8 A202K2G_M
10 A202K2H_M
12 A202K2K_M
100 2 A202K3B_M
3 A202K3C_M
4 A202K3D_M
5 A202K3E_M
6 A202K3F_M
8 A202K3G_M
10 A202K3H_M
12 A202K3K_M
200
Additional models with higher continuous amperes available.
Consult the Controls Catalog (CA08102001E), Tab 37 for a full
model listing.
300
400
1
The underscore (_) indicates missing code letter for magnet coil selection, see table below.
2
Lighting contactors are not available with DC coils.
A202 Magnet Coil – Selection
Coil Voltage/Hertz
Catalog
Number Suffi x Coil Voltage/Hertz
Catalog
Number Suffi x
120/60 A 600/60 E
208/60 B 120/60, 110/50 A
277/60 Z 220/50, 240/60 Q
440/50, 480/60 X 24/60 I
3
3
Available in 2- to 5-pole, 30 and 60A devices and on 2- to 3-pole, 100 and 200A devices.
CN35 Electrically Held – Overview
• Easy to install and maintain
• Full line of Freedom snap-on accessories
• Standard with 1NO auxiliary contact
CN35 Contactors – Model Selection
Maximum Ampere Rating
4
Number of Poles
Open Type
Catalog Number
5
10 2 CN35AN2_B
3 CN35AN3_B
4 CN35AN4_B
20 2 CN35BN2_B
3 CN35BN3_B
4 CN35BN4_B
6 CN35BN6_B
9 CN35BN9_B
12 CN35BN12_B
30 2 CN35DN2_B
3 CN35DN3_B
4 CN35DN4_B
5 CN35DN5_B
6 CN35DN6_B
9 CN35DN9_B
12 CN35DN12_B
60 2 CN35GN2_B
3 CN35GN3_B
4
6
CN35GN4_B
5
6
CN35GN5_B
100 2 CN35KN2_
3 CN35KN3_
200
Additional models with higher maximum amperes ratings
available. Consult the Controls Catalog (CA08102001E), Tab 37
for a full model listing.
300
400
7
4
The listed ampere ratings are based on a maximum load voltage of 480V for tungsten lamp
applications and 600V for ballast or mercury vapor type applications.
5
The underscore (_) indicates missing code letter for magnet coil selection, see table below.
6
Additional power poles mounted on side(s) of contactor.
7
UL ballast and resistive ratings only.
CN35 Magnet Coil – Selection
Coil Voltage/Hertz
8
Catalog
Number Suffi x Coil Voltage/Hertz
Catalog
Number Suffi x
120/60, 110/50 A 380-415/60 L
240/60, 220/50 B 550/50 N
480/60, 440/50 C 24/60, 24/50
10
T
600/60, 550/50 D 24/50 U
208/60 E 32/50 V
277/60 H 48/60 W
208-240/60
9
J 48/50 Y
240/50 K
8
For DC magnet coils, see the Controls Catalog (CA08102001E), Tab 33.
9
For 10, 20 and 30A sizes only.
10
For 10, 20 and 30A sizes only. Sizes 60-400A are 24V/60Hz only.