Product Brochure

Volume 5—Motor Control and Protection CA08100006E—May 2013 www.eaton.com V5-T4-3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4.1
Definite Purpose Contactors and Starters
Product Overview—Contactors and Starters
Catalog Number Selection
Definite Purpose Control—Contactors and Starters
Note
1
Not available on 50A devices.
Model
C = Contactor
A = Three-phase starter
B = Single-phase starter
Type
25 = Non-reversing contactors and starters (C306)
27 = Non-reversing starters (XTOB)
30 = Non-reversing starters (C440 EOL)
65 = Reversing contactors
C 2 5 D N A 2 1 5 A A 1 6 1 - 8 4
Contactor Frame Size
A = Compact, single-pole
B = Compact, two-pole
C = Compact, single-pole w/shunt
D = 15–50A, two- and three-pole
E = 25–40A, four-pole
F = 60–75A, two- and three-pole
G = 90A, two- and three-pole
H = 120A, two- and three-pole
K = 200 and 300A, three-pole
L = 360A, three-pole
For Starters Only
C = Common control wiring
S = Separate control wiring
Enclosure Type
N = Open with metal mounting plate
R = Open with DIN rail mounting adapter
(two- and three-pole, 15–50A contactors only)
G = NEMA Type 1 Enclosed
Number of Poles
1 = Single-pole
2 = Two-pole
3 = Three-pole
4 = Four-pole
Options
Blank = Individual pkg.
GL = Global listed
-84 = 20 pc./pkg. (C25D_)
50 pc./pkg. (C25A_, C25B_, C25C_)
-86 = Rotate coil terminals 180° for
15A–50A contactors
Fuse Blocks
161 = Class M, 600V, 30A
237 = Class G, 300V, 15A
238 = Class G, 300V, 20A
231 = Class G, 300V, 30A
232 = Class G, 300V, 60A
361 = Class J, 600V, 30A
362 = Class J, 600V, 60A
431 = Class T, 300V, 30A
432 = Class T, 300V, 60A
461 = Class T, 600V, 30A
462 = Class T, 600V, 60A
521 = Class H, 250V, 30A
522 = Class H, 250V, 60A
621 = Class R, 250V, 30A
622 = Class R, 250V, 60A
Power Terminals
A = Binding head screw
B = Binding head screw and quick connect terminals (side-by-side)
C = Screw/pressure plate
1
D = Screw/pressure plate and quick connect terminals (side-by-side)
1
E = Box lugs (posidrive setscrew)
F = Box lugs (posidrive setscrew) and quick connect
terminals (side-by-side)
G = Binding head screw and quick connect terminals (vertical in-line)
H = Screw/pressure plate and quick connect terminals (vertical in-line)
1
J = Box lugs (posidrive setscrew) and quick connect terminals
(vertical in-line)
K = Box lugs (hex socket allen head setscrew)
L = Box lugs (hex socket allen head setscrew) and quick connect
terminals (side-by-side)
M = Box lugs (hex socket allen head setscrew) and quick connect
terminals (vertical in-line)
Auxiliary Contacts (Side Mount)
A = 1NO pressure plate
B = 1NC pressure plate
C = 1NO-1NC pressure plate
D = 2NO pressure plate
E = 2NC pressure plate
F = 1NO pressure plate and QC
G = 1NC pressure plate and QC
H = 1NO-1NC pressure plate and QC
J = 2NO pressure plate and QC
K = 2NC pressure plate and QC
L = 1NO-1NC snap switch QC only
M = 2NO-2NC snap switch QC only
Coil Selection
A = 110–120 Vac, 50/60 Hz
B = 208–240 Vac, 50/60 Hz
C = 440–480 Vac, 50/60 Hz
D = 550–600 Vac, 50/50 Hz
H = 277 Vac, 60 Hz
J = 220–240 Vac, 50/60 Hz
L = 380–415 Vac, 50 Hz
R = 12 Vac, 50/60 Hz
T = 24 Vac, 50/60 Hz
1R = 12 Vdc
1T = 24 Vdc
1W = 48 Vdc
1A = 120 Vdc
Current Rating
15 =15A
25 =25A
30 =30A
40 =40A
50 =50A
60 =60A
75 = 75A
90 = 90A
120 = 120A
200 = 200A
300 = 300A
360 = 360A