Datasheet
04/18/2017 185163 - HPL-ED2017 V31.0 EN 2 / 3
Technical�data
General
Standards   IEC/EN 60947-5-5
VDE 0660
Certifications   CE, UL, CSA
Operating frequency Operations/h 
 300
Actuating force  n
 50
Tightening torque Threaded ring  Nm 2
Climatic proofing   Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection   IP66, IP67, IP69K (front)
IP65 (on rear)
Mounting position   As required
Mechanical shock resistance, shock duration 11 ms  g > 30
Contacts
Rated impulse withstand voltage U
imp
V AC 4000
Rated insulation voltage U
i
V 250
Overvoltage category/pollution degree   III/3
Control circuit reliability   
At 17 V DC/7 mA H
F
N/C contact: statistically determined 1 failure per 0.9 × 10
6
 Operations
Max. short-circuit protective device   
Fuse gG/gL A 4
Rated conditional short-circuit current Iq kA 1
Switching�capacity
Rated operational current I
e
A 
AC-15   
24 V I
e
A 4
DC-13   
24 V I
e
A 3
Cable characteristics   
Design   Cable end open
Cable Length  m 3.5
Material characteristic   PUR
Diameter mm 4.7
Design�verification�as�per�IEC/EN�61439
Technical data for design verification   
Operating ambient temperature min.  °C -25
Operating ambient temperature max.  °C 70
Technical�data�ETIM�6.0
Low-voltage industrial components (EG000017) / Emergency stop complete (EC002034)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / EMERGENCY-STOP pushbutton, complete device
(ecl@ss8.1-27-37-12-44 [ACN986008])
Unlocking method   Turn unlatching mechanism
Number of contacts as normally closed contact   2
Number of contacts as normally open contact   0
Degree of protection (IP)   -
Mounting method   Built-in
With lighting   No
Hole diameter  mm 22
Connection type auxiliary circuit   -
Diameter cap  mm 45