Airflow management and racks
Airflow management and racks
Active Airflow Manager
Eaton’s HCS pressure based system with active airflow, when
combined with best practices, improves performance metrics
considerably. Allocating the correct amount of airflow at known
intake locations is the key to reducing energy consumption while
increasing equipment performance. Best practices such as blanking
panels, proper perforated tile placement and the reduction of bypass
airflow must be employed to ensure desired results.
Features and benefits
• SNMPmanageddevicewithuser-friendlyWebinterface
• Controllercontinuouslymonitorspressuredifferentialstoensure
that air entering the enclosure and server is properly removed
• LocalLEDsindicatefanstatusincludingfanfailandover
temperature
• Manageupto64peerActiveAirflowManagersviaEthernet
• Twointegratedtemperaturesensorswithe-mailalertcapabilities
• Redundantpowerinput;C13plugtypeisrequiredforeachinput,
90-240 Vac supplied by enclosure PDU(s)
• ControllerisRoHScompliant
HCS for third-party racks
Convert existing enclosures to the HCS to eliminate the incremental
capital expense associated with having to add more CRAC units or
other supplemental cooling.
Features and benefits
• Implementheatcontainmentwithminimalinterruptionto
operations by building up from existing enclosures without having
to re-route or disconnect cables and power
• Byisolatingthehotexhaustairfromthecoldsupplyair,youcan
load over 25 kW of equipment in an enclosure
• Requiresnoadditionalairconditionersorotherspaceconsuming
supplemental equipment at the perimeter of the data center,
in-row or overhead
• Eliminateschaosairflowresultsinamorepredictableoperating
environment, allowing you to drive efficient energy use and create
a reliable infrastructure for moves, additions and changes
Environmental Rack Monitor (ERM)
Eaton’s ERM guards against environmental threats by continuously
monitoring temperature and humidity at two locations in an
enclosure, plus the status of up to four additional contact sensor
devices (such as detectors for smoke, vibration or fire), for a total
of eight sensors per monitor. In a typical rack application, the low
profile, freestanding base unit can be placed horizontally or vertically
in unused space. The temperature/humidity sensor units can be
placed anywhere in the enclosure.
Features and benefits
• Monitorsenvironmentalconditionstoprotectvaluableassets
from heat, humidity, smoke, vibration, water leaks or intrusion
• Displaysreal-timeandhistoricalstatusofallsensorstoaPC,
Internet-ready wireless device or Network Management System
(NMS) software
• Aggregatesreal-timeinformationfromupto100ERMsinasingle
Web page
• Automaticallynotifiesdesignatedrecipientsofout-of-range
conditions, via email, SNMP, PDA or pager
• Simplifiesoperationswithanintuitive,Webbrowserinterface,
rich graphing of data, auto-discovery and auto-aggregation
utilities, and more
Eaton 9140 UPS
with ERM and
Environmental
Monitoring Probe.