Specifications

42 Distribution Products Catalog CA08101001E—October 2010 www.eaton.com
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16.4
Tr a n s f er Switches
Magnum-Based Designs
Floor-Standing Magnum Transfer Switch
Contents
Description Page
Floor-Standing Magnum Transfer Switches
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . 46
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . 47
Technical Data and Specifications . . . . . . . . . . . . . . . . . . 47
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Bypass Isolation Transfer Switch . . . . . . . . . . . . . . . . . . . . 51
Magnum Closed Transition Soft Load Transfer Switches
with ATC-5000 Controller . . . . . . . . . . . . . . . . . . . . . . . . . 57
ATC-5000 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Floor-Standing Magnum Transfer Switches
Product Description
Eaton’s Magnum transfer
switches are designed for a
variety of standby power
applications for critical and
noncritical loads. They
monitor both Source 1
(Normal) and Source 2
(Emergency) power sources.
In the event of a Source 1
power interruption, these
switches will automatically
transfer the load circuits to
the Source 2 power source.
Once Source 1 power source
has been restored, the
process is automatically
reversed.
Application Description
The Magnum family of
transfer switches covers
applications ranging from 200
to 5000A through 600 Vac.
Some of the applications are:
automatic or non-automatic
configurations, open or
closed transition and standard
or rated suitable for use as
service entrance. They are
designed for applications
where total system
coordination must be
accomplished
while achieving
a high level of Withstand,
Interrupting, and Closing
performance.
Drawout construction is
available for applications,
such as critical life-support
systems, where preventive
maintenance, inspection
and testing must be
accomplished while
maintaining continuity of
power to the load.
Features, Benefits and Functions
Freestanding
Magnum insulated case
devices
Fastest switching times
available (<3 cycles)
High withstand ratings
Full 60-cycle short-time
withstand capability
Safe manual transfer
under load
Multi-tap voltage
selection plug
Integral service entrance
capability
Integral overcurrent
protection capability
Drawout capability
Programmable
microprocessor
controller with keypad
entry and display
Communications capable
Durable powder-coated
steel enclosures
UL 489 and UL 1008 listed.
4000 and 5000A available
as UL 891 only
85–100 kA standard
withstand ratings
30-cycle, extended
withstand ratings
Electrically operated
True four-pole switched
neutral availability
Totally enclosed
contact assembly