Specifications
42 Distribution Products Catalog CA08101001E—October 2010 www.eaton.com
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16.4
Tr a n s f er Switches
Magnum-Based Designs
Floor-Standing Magnum Transfer Switch
Contents
Description Page
Floor-Standing Magnum Transfer Switches
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . 46
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . 47
Technical Data and Specifications . . . . . . . . . . . . . . . . . . 47
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Bypass Isolation Transfer Switch . . . . . . . . . . . . . . . . . . . . 51
Magnum Closed Transition Soft Load Transfer Switches
with ATC-5000 Controller . . . . . . . . . . . . . . . . . . . . . . . . . 57
ATC-5000 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Floor-Standing Magnum Transfer Switches
Product Description
Eaton’s Magnum transfer
switches are designed for a
variety of standby power
applications for critical and
noncritical loads. They
monitor both Source 1
(Normal) and Source 2
(Emergency) power sources.
In the event of a Source 1
power interruption, these
switches will automatically
transfer the load circuits to
the Source 2 power source.
Once Source 1 power source
has been restored, the
process is automatically
reversed.
Application Description
The Magnum family of
transfer switches covers
applications ranging from 200
to 5000A through 600 Vac.
Some of the applications are:
automatic or non-automatic
configurations, open or
closed transition and standard
or rated suitable for use as
service entrance. They are
designed for applications
where total system
coordination must be
accomplished
while achieving
a high level of Withstand,
Interrupting, and Closing
performance.
Drawout construction is
available for applications,
such as critical life-support
systems, where preventive
maintenance, inspection
and testing must be
accomplished while
maintaining continuity of
power to the load.
Features, Benefits and Functions
●
Freestanding
●
Magnum insulated case
devices
●
Fastest switching times
available (<3 cycles)
●
High withstand ratings
●
Full 60-cycle short-time
withstand capability
●
Safe manual transfer
under load
●
Multi-tap voltage
selection plug
●
Integral service entrance
capability
●
Integral overcurrent
protection capability
●
Drawout capability
●
Programmable
microprocessor
controller with keypad
entry and display
●
Communications capable
●
Durable powder-coated
steel enclosures
●
UL 489 and UL 1008 listed.
4000 and 5000A available
as UL 891 only
●
85–100 kA standard
withstand ratings
●
30-cycle, extended
withstand ratings
●
Electrically operated
●
True four-pole switched
neutral availability
●
Totally enclosed
contact assembly